Schneider Electric DIN Rail Circuit Trip for use with GV3L, GV2P, GV3P, GV2MEGV2LE, GV2L
- RS Stock No.:
- 219-8319
- Mfr. Part No.:
- GVAU115
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£33.61
(exc. VAT)
£40.33
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 8 unit(s) ready to ship
- Plus 10 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £33.61 |
*price indicative
- RS Stock No.:
- 219-8319
- Mfr. Part No.:
- GVAU115
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Circuit Trip | |
| Range | TeSys | |
| Series | TeSys | |
| For Use With | GV3L, GV2P, GV3P, GV2MEGV2LE, GV2L | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw Clamp | |
| Standards/Approvals | EN/IEC 60947-3 | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Circuit Trip | ||
Range TeSys | ||
Series TeSys | ||
For Use With GV3L, GV2P, GV3P, GV2MEGV2LE, GV2L | ||
Mount Type DIN Rail | ||
Terminal Type Screw Clamp | ||
Standards/Approvals EN/IEC 60947-3 | ||
- COO (Country of Origin):
- CZ
Schneider Electric GVAU115
TeSys GV electrical trip, MN undervoltage release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
The Schneider Electric GVAU115 is aTeSys GV electrical trip unit, MN under voltage release, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals.
Toxic heavy metal free
Mercury free
Related links
- Schneider Electric 110 → 130 V ac, 125V dc Circuit Trip for use with TeSys GV4
- Schneider Electric 110 → 130 V dc, 230 → 415V ac Shunt Trip Shunt trip for use with NG125 Series
- Schneider Electric 440V ac Circuit Breaker Circuit Trip for use with Circuits
- Schneider Electric 690V ac Circuit Trip for use with Compact NSX 160/250 Circuit Breakers
- Schneider Electric 690V ac Circuit Trip for use with Compact NSX 100 Circuit Breakers
- Schneider Electric 690V ac Circuit Trip Circuit Trip for use with Circuit Breaker
- Schneider Electric 690V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
- Schneider Electric 690V ac Circuit Trip for use with Compact NSX 250 Circuit Breakers