Schneider Electric Auxiliary Contact, 2 Contact, 2 NO, Acti9 iCT, DIN Rail, 2 A, 130 V dc, 24 V dc, 240V ac, A9C15916
- RS Stock No.:
- 791-2840
- Mfr. Part No.:
- A9C15916
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£67.26
(exc. VAT)
£80.71
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 9 unit(s) ready to ship
- Plus 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £67.26 |
*price indicative
- RS Stock No.:
- 791-2840
- Mfr. Part No.:
- A9C15916
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Auxiliary Contact | |
| Number of Contacts | 2 | |
| Normal State Configuration | 2 NO | |
| Series | Acti9 iCT | |
| Mount Type | DIN Rail | |
| Contact Current | 2A | |
| Terminal Type | Screw | |
| Pole and Throw Configuration | 2P | |
| Contact Voltage | 130, 24, 240V dc | |
| Operational Current Ie | 5A | |
| Rated Insulation Voltage Ui | 440V | |
| Mounting Location | Right Side | |
| Minimum Operating Temperature | -5°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Auxiliary Contact | ||
Number of Contacts 2 | ||
Normal State Configuration 2 NO | ||
Series Acti9 iCT | ||
Mount Type DIN Rail | ||
Contact Current 2A | ||
Terminal Type Screw | ||
Pole and Throw Configuration 2P | ||
Contact Voltage 130, 24, 240V dc | ||
Operational Current Ie 5A | ||
Rated Insulation Voltage Ui 440V | ||
Mounting Location Right Side | ||
Minimum Operating Temperature -5°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
RoHS Status: Exempt
- COO (Country of Origin):
- FR
Acti9 iACT Auxiliary Contactors
Acti9 iACT Auxiliary Contactors are suitable for iCT contactors, these auxiliaries allow different operations
iACTs allows indication or control of the "open"or "closed" position of the contactor power contacts
iACTp is an interference suppressor which limits overvoltages on the control circuit
iACTc is used to control a contactor in impulse-type mode or to combine latched or impulse-type control orders
iACT24 allows control and indication of a 230 Vac contactor from the Acti 9 Smartlink or by a PLC, by 24 V DC signals
iATEt is used to time delay for iCT and iTL