Allen Bradley Auxiliary Contact, 2 Contact, 1 NO/1 NC, 194, Front, 100 A, 500V dc, 194E-A-P11

Subtotal (1 unit)*

£11.38

(exc. VAT)

£13.66

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 19 unit(s) shipping from 27 April 2026
  • Plus 17 unit(s) shipping from 27 April 2026
  • Plus 80 unit(s) shipping from 08 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£11.38

*price indicative

RS Stock No.:
422-9299
Distrelec Article No.:
302-26-758
Mfr. Part No.:
194E-A-P11
Brand:
Allen Bradley
Find similar products by selecting one or more attributes.
Select all

Brand

Allen Bradley

Number of Contacts

2

Product Type

Auxiliary Contact

Normal State Configuration

1 NO/1 NC

Series

194

Contact Current

100A

Mount Type

Front

Terminal Type

Screw

Pole and Throw Configuration

2P

Contact Voltage

500V dc

Minimum Operating Temperature

-20°C

Mechanical Durability

1Mcycles

Operational Current Ie

100A

Rated Insulation Voltage Ui

690V

Maximum Operating Temperature

55°C

Standards/Approvals

IEC, VDE, BS

RoHS Status: Exempt

COO (Country of Origin):
PL

Allen Bradley Auxiliary Contact Block, NO/NC, DPDT - 194E-A-P11


Searching for a reliable accessory for your industrial circuit breaker? Choose this auxiliary contact block from Rockwell Automation's Allen Bradley range. This component accommodates cables ranging in size from 0.75 to 2.5mm², making it a versatile choice for use in a range of applications. It has one normally open (NO) contact and one normally closed (NC) contact and can be mounted to the side of a circuit breaker without the need for specialised tools, making it simple to install.

• Contact current rating of 6A for use in low-current applications• Wide operating temperature range of -20°C to +55°C for use in a variety of demanding environments• Screw terminals for simple and secure connections• Recyclable block components and materials for increased sustainability

Standards and Certifications


• CE (Conformité Européenne)• CCC (China Compulsory Certificate)• IEC (International Electrotechnical Commission)

How often should low-voltage circuit breakers be inspected and maintained?


Low-voltage circuit breakers don't need much maintenance, but they should be inspected and tested at least once every one to three years to maintain reliable levels of safety and efficiency.

4th Pole, Neutral Terminal & Auxiliary Contacts for Base Mounting Switch


Common auxiliary blocks can be fitted without the use of tools as can the fourth pole. Auxiliary contacts are rated at 17Vdc, 5mA (DIN 19240)

4th pole is early make, late break. Fully rated neutral

Insulation voltage Ui 690V. Thermal current 12A; rated current 6A

Operating temperature rating -20 to + 55°C

Maximum cable size 0.75 to 2.5mm²

Allen Bradley MCS Range


The 194E switch disconnector range forms part of the Modular Control System (MCS) 9mm grid system and similarly features compact design, modularity and extensive choice. All switch materials can be recycled. Universal terminal screws are fitted for ’Pozidriv’ or flat blade screwdriver. The switching category is AC23A.

Note

The 1NO + 1NC auxiliary contacts are available in standard and make-before-break (MBB) versions

Approvals

UL, CSA

Standards

IEC 947, VDE 0660