    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    755 Products showing for Signal Conditioners

    PR Electronics
    Universal Signal Converter
    Current, Voltage
    Current, Voltage
    0 → 20 mA, 0/0.2 → 1 V dc, 0/1 → 5 V dc, 0/2 → 10 V dc, 4 → 20mA
    (Active Bipolar) 0 → 20 mA, (Active Unipolar) 0 → 20 mA, (Passive 2-Wire) 0 → 20 mA, (Unipolar) 0 → 23 mA, (Bipolar) 0/0.2 → 1 V dc, 0/1 → 10 V dc, 0/1 → 5 V dc, -23 → +23 mA, (Active Bipolar) 4 → 20 mA, (Active U
    19.2 → 300 V dc, 21.6 → 253V ac
    -
    DIN Rail Mount
    -20 → +60°C
    -
    -
    4
    Seneca
    Universal Converter
    Current, Linear Resistance, Potentiometer, Pulse, RTD, Thermocouple, Voltage
    Current, Voltage
    B, Bipolar From 75 mV → 20 V, E, K, KTY81, KTY84, N, Ni100, NTC, Pt100, Pt500, Pt1000, R, S, T, Type J, up → 20 mA
    0/1..5V, 0/2..10V, 0/4..20 mA
    10 → 40V
    -
    -
    -
    -
    -
    Z109REG2-1
    Pepperl + Fuchs
    Isolation Amplifier
    Current, Voltage
    Current, Voltage
    30 V, 50 mA, 0 → 10 V, 0 → 20 mA, 2 → 10 V, 4 → 20mA
    0 → 10 V, 0 → 20 mA, 2 → 10 V, 4 → 20mA
    16.8 → 31.2V dc
    -
    DIN Rail Mount
    -25 → +70°C
    -
    -
    S1SD
    PR Electronics
    Signal Isolator
    Current, Voltage
    Current, Voltage
    0 → 10.25 V, 0 → 20.5mA
    0 → 10 V dc, 0 → 20.5mA
    16.8 → 31.2V dc
    ATEX
    DIN Rail Mount
    -25 → +70°C
    -
    -
    3100
    Phoenix Contact
    Power Terminal Block
    Voltage
    Voltage
    9.9 → 30V dc
    9.6 → 29.7V dc
    9.6 → 30V dc
    -
    DIN Rail Mount
    -40 → +70°C
    -
    -
    MINI MCR
    PR Electronics
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Crouzet
    Analogue Signal Converter
    Current
    Voltage
    0 → 20mA
    0 → 10V dc
    24V
    -
    -
    -
    -
    -
    3RS7005
    PR Electronics
    Hart Transparent Driver
    Current, Voltage
    Current
    3.5 → 23mA
    0 → 23mA
    19.2 → 31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    9100
    PR Electronics
    Isolated Repeater
    Current
    Current
    0 → 20.5mA
    0 → 20.5mA
    16.8 → 31.2V dc
    ATEX
    DIN Rail Mount
    -25 → +70°C
    -
    -
    3100
    PR Electronics
    Solenoid/Alarm Driver
    NPN, PNP
    Relay
    -
    -
    19.2 → 31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    9200
    PR Electronics
    Hart Transparent Repeater
    Current
    Current, Relay
    -
    -
    19.2 → 31.2V dc
    ATEX
    -
    -20 → +60°C
    -
    -
    9100
    Weidmüller
    Signal Isolator
    Current
    Current
    4 → 20mA
    4 → 20mA
    19.2 → 31.2V
    IECEx
    DIN Rail Mount
    -20 → +60°C
    -
    -
    ACT20X
    WAGO
    Isolating Amplifier
    Voltage
    Current
    0 - 10V dc
    4 - 20mA
    24V dc
    -
    -
    -
    -
    -
    857
    Weidmüller
    Signal Converter
    Resistance
    Analogue
    0 → 10V
    4 → 20mA
    60V dc
    -
    -
    -
    -
    -
    ACT20P
    ifm electronic
    Amplifier
    NPN, PNP
    Relay
    -
    -
    110 → 240V ac
    -
    -
    -
    -
    -
    DN
    Weidmüller
    Signal Converter
    Current
    Current
    4 → 20mA
    4 → 20mA
    -
    ATEX, IECEx
    -
    -
    -
    -
    ACT20P
    Phoenix Contact
    Isolation Amplifier
    Voltage
    Current, Voltage
    -1 → 3 V, -800 → 800mV
    0 → 10 V, 0 → 20mA
    19.2 → 30V dc
    -
    DIN Rail Mount
    -20 → +65°C
    -
    -
    MACX
    WAGO
    Isolation Amplifier
    Current, Voltage
    Current, Voltage
    0 → 1 V, 0 → 10 mA, 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 2 → 10 mA, 4 → 20mA
    0 → 10 V, 0 → 10 mA, 0 → 20 mA, 2 → 10 V, 2 → 10 mA, 4 → 20mA
    24V dc
    -
    DIN Rail Mount
    -40 → +70°C
    -
    -
    857
    PR Electronics
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    PR Electronics
    Universal Signal Converter
    Universal
    Relay
    0 → 12 V dc, 0 → 20mA
    2 A, 250V
    19.2 → 300 V dc, 21.6 → 253V ac
    -
    DIN Rail Mount
    -20 → +60°C
    -
    -
    4100