RCDs

An RCD (residual current device), has been designed to protect you from fatal electric shocks as it automatically switches off electricity when there is a fault. This potentially life-saving device protects against electrocution in instances where there is a bare wire, over-heating or earth faults. RCDs are also known as an RCCB (residual-current circuit breaker) in the UK but in the United States and Canada they are referred to as a GFCI (ground fault circuit interrupter). If RCDs are regularly tested, they are reliable life-saving devices, reducing the risk of electric shock and protecting your home against electrical fires. strongHow does an RCD work?/strong An RCD is placed within the circuits it has to protect. By monitoring the electric current, it can quickly detect when a circuit fails and electricity is flowing incorrectly. When the fault is detected, the RCD switches off the circuit so that the person handling the wires comes to no harm. RCDs are often integrated with a fuse or a href="/web/c/automation-control-gear/circuit-protection-circuit-breakers/mcbs/" target="_self"MCB (miniature circuit breaker)/a adding protection when there are excessive current causing spikes or surges in the circuit. strongTypes of RCD/strong ulliFixed RCDs: they are installed in a fuse box and are used for both industrial and domestic applications. They protect lots of circuits and provide an excellent level of protection. RCDs located within a consumer power distribution unit are mostly passive. This allows household appliances to re-establish normal operation when the circuit power is restored./liliSocket-Outlet RCDs: they provide individual protection to the person who is in contact with the equipment. They can be used in place of a standard socket outlet. Socket-outlet RCDs are either active or passive. They are latching in operation so are not ideal for power tools which do not require a restart when the circuit is restored./liliPortable RCDs: they also only provide individual protection to the person who is in contact with the equipment. They plug into any standard socket, and the appliance is then plugged into the RCD. Portable RCDs are mostly active and unlatch when any abnormality is detected. People who use outside power tools would benefit from a portable RCD as their equipment could become dangerous if they were suddenly reactivated./li/ul

...
Read more Read less

Filters

Viewing 41 - 60 of 440 products
Results per page
Description Price Number of Poles Current Rating Model Number Trip Sensitivity Rated AC Voltage Rated DC Voltage Mounting Style Range Break Time Series Application Breaking Capacity Circuit Breaker Type Earth Leakage Protection Type
RS Stock No. 124-7727
Mfr. Part No.5SV3312-6
BrandSiemens
£103.76
Each
Units
2 25 A 5SV33126 30mA 230 V ac - DIN Rail Sentron Instantaneous 5SV3 Industrial, Non-Residential, Residential - RCCB -
RS Stock No. 922-8673
Mfr. Part No.PFIM-40/4/01-A-MW
BrandEaton
£103.97
Each
Units
4 40 A - 100mA 230 → 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 922-8718
Mfr. Part No.PKNM-10/1N/B/003-A-MW
BrandEaton
£69.28
Each
Units
2 10 A - 30mA 230 V - DIN Rail PKNM Instantaneous PKNM - - MCB, RCD -
RS Stock No. 922-8721
Mfr. Part No.PKNM-16/1N/C/003-A-MW
BrandEaton
£69.28
Each
Units
2 16 A - 30mA 230 V - DIN Rail PKNM Instantaneous PKNM - - MCB, RCD -
RS Stock No. 922-8737
Mfr. Part No.PKNM-20/1N/C/003-A-MW
BrandEaton
£69.28
Each
Units
2 20 A - 30mA 230 V - DIN Rail PKNM Instantaneous PKNM - - MCB, RCD -
RS Stock No. 806-7206
Mfr. Part No.A9V03663
£148.00
Each
Units
2P 63 A - 100mA 240 V - DIN Rail Mount Acti 9 - Vigi - - - -
RS Stock No. 863-7751
Mfr. Part No.4 115 06
BrandLegrand
£56.32
Each
Units
2 63 A - 30mA 230 V - DIN Rail - - 4115 - - - -
RS Stock No. 866-2662
Mfr. Part No.7660S
£71.49
Each
Units
- 63 A - 300mA 230 V - DIN Rail Mount Sentry Instantaneous 7660S - - - -
RS Stock No. 776-8722
Mfr. Part No.A9V10225
£134.00
Each
Units
2 25 A - 10mA 400 V - DIN Rail Acti 9 Instantaneous iC60 - - - -
RS Stock No. 490-197
Mfr. Part No.236772
BrandEaton
£68.66
Each
Units
4 25 A - 30mA 400 V - DIN Rail PXF - PXF-A - - - -
RS Stock No. 667-0602
Mfr. Part No.235394
BrandEaton
£84.45
Each
Units
2 40 A - 30mA - - - XBoard - PFIM - - - -
RS Stock No. 922-8639
Mfr. Part No.PFIM-63/4/003-MW
BrandEaton
£123.18
Each
Units
4 63 A - 30mA 230 → 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 863-7767
Mfr. Part No.4 117 02
BrandLegrand
£62.61
Each
Units
4 25 A - 30mA 400 V - DIN Rail - - 4117 - - - -
RS Stock No. 790-9446
Mfr. Part No.A9D55610
£146.00
Each
Units
- 10 A - 30mA 230 V - DIN Rail Mount Acti 9 Instantaneous iDPN - - - -
RS Stock No. 922-8636
Mfr. Part No.PFIM-80/4/003-MW
BrandEaton
£149.10
Each
Units
4 80 A - 30mA 230 → 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 922-8614
Mfr. Part No.PFIM-25/4/003-MW
BrandEaton
£81.98
Each
Units
4 25 A - 30mA 230 → 400 V - DIN Rail PFIM Instantaneous PFIM - - RCCB -
RS Stock No. 866-2659
Mfr. Part No.7560S
£69.20
Each
Units
- 63 A - 100mA 230 V - DIN Rail Mount Sentry Instantaneous 7560S - - - -
RS Stock No. 667-0627
Mfr. Part No.235402
BrandEaton
£106.93
Each
Units
2 80 A - 30mA - - - XBoard - PFIM - - - -
RS Stock No. 734-9595
Mfr. Part No.A9N21443
£174.85
Each
Units
- 10 A - 300mA 400 V - - Acti 9 - DT40 - - - -
RS Stock No. 922-8715
Mfr. Part No.PKNM-10/1N/C/003-A-MW
BrandEaton
£69.28
Each
Units
2 10 A - 30mA 230 V - DIN Rail PKNM Instantaneous PKNM - - MCB, RCD -
Related Products
From Siemens the 5SV3 series are RCCBs suitable ...
Description:
From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality. Residual current operated circuit breaker for personnel and fire protection Silicone free2 or 4 ...
From Siemens the 5SV3 series are RCCBs suitable ...
Description:
From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality. Residual current operated circuit breaker for personnel and fire protection Silicone free2 or 4 ...
Allen Bradley general purpose RCDs from the 1492 ...
Description:
Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted. 2 or 4 pole versions DIN Rail mount Screw Terminals. ...
With integrated mounting rail for right-aligned mounting of ...
Description:
With integrated mounting rail for right-aligned mounting of 2, 3 and 4-pin automatic cut-outs in S200 series Neutral conductor connector can be mounted to right or left Applications: escalators, lifts, electrically-operated gates and barriers, machine tools, car washes, assembly lines and conveyor belts.