Select all | Attribute | Value |
|---|---|---|
| Brand | Kane | |
| Best Carbon Monoxide Accuracy | ±5% | |
| Carbon Monoxide Resolution | 1ppm | |
| Best Carbon Dioxide Accuracy | ±0.3% | |
| Carbon Dioxide Resolution | 0.1% | |
| Best Oxygen Level Accuracy | ±0.3% | |
| Oxygen Level Resolution | 0.1% | |
| Maximum Temperature | +50 (Internal) °C, +600 (External) °C, +600 (Flue) °C | |
| Best Temperature Measurement Accuracy | ±0.3 (External) %, ±0.3 (Flue) %, ±0.3 (Internal) % | |
| Temperature Measurement Resolution | ±0.1 (External) °C, ±0.1 (Flue) °C, ±0.1 (Internal) °C | |
| Minimum Oxygen Level | 0% | |
| Maximum Operating Temperature | +45°C | |
| Maximum Carbon Dioxide Level | 20% | |
| Weight | 800g | |
| Minimum Carbon Monoxide Level | 0ppm | |
| Battery Type | AA | |
| Maximum Carbon Monoxide Level | 20 ppm, >2000 (Purge Pump Operate) ppm, 2000 (Nom) ppm | |
| Leak Testing | Yes | |
| Minimum Operating Temperature | 0°C | |
| Maximum Oxygen Level | 21% | |
| Model Number p | KANE458 | |
| Height | 90mm | |
| Width | 45mm | |
| Battery Life | 8 h | |
| Length | 200mm | |
| Power Source | Battery | |
| Minimum Carbon Dioxide Level | 0% | |
Select all | ||
|---|---|---|
Brand Kane | ||
Best Carbon Monoxide Accuracy ±5% | ||
Carbon Monoxide Resolution 1ppm | ||
Best Carbon Dioxide Accuracy ±0.3% | ||
Carbon Dioxide Resolution 0.1% | ||
Best Oxygen Level Accuracy ±0.3% | ||
Oxygen Level Resolution 0.1% | ||
Maximum Temperature +50 (Internal) °C, +600 (External) °C, +600 (Flue) °C | ||
Best Temperature Measurement Accuracy ±0.3 (External) %, ±0.3 (Flue) %, ±0.3 (Internal) % | ||
Temperature Measurement Resolution ±0.1 (External) °C, ±0.1 (Flue) °C, ±0.1 (Internal) °C | ||
Minimum Oxygen Level 0% | ||
Maximum Operating Temperature +45°C | ||
Maximum Carbon Dioxide Level 20% | ||
Weight 800g | ||
Minimum Carbon Monoxide Level 0ppm | ||
Battery Type AA | ||
Maximum Carbon Monoxide Level 20 ppm, >2000 (Purge Pump Operate) ppm, 2000 (Nom) ppm | ||
Leak Testing Yes | ||
Minimum Operating Temperature 0°C | ||
Maximum Oxygen Level 21% | ||
Model Number p KANE458 | ||
Height 90mm | ||
Width 45mm | ||
Battery Life 8 h | ||
Length 200mm | ||
Power Source Battery | ||
Minimum Carbon Dioxide Level 0% | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Kane Combustion Gas Analyser
Features and Benefits
• Rotary switch for ease of use
• Data hold
• Logs and prints reports for combustion, pressure, let-by & tightness, temperature, CO build up and commission test
• Optional infrared printer option available
• 5-year warranty, if serviced annually by Kane
Applications
• Safety checks
• CO in a room or around an appliance
• Combustion performance checks
• Combustion efficiency checks
• Flue draught