HPMA115S0-XXX Honeywell, Air Quality Sensor, UART 8-Pin
- RS Stock No.:
- 145-4279
- Mfr. Part No.:
- HPMA115S0-XXX
- Brand:
- Honeywell
Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
- RS Stock No.:
- 145-4279
- Mfr. Part No.:
- HPMA115S0-XXX
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Honeywell | |
Sensor Type | Light | |
Mounting Type | Surface Mount | |
Pin Count | 8 | |
Dimensions | 43 x 36 x 23.7mm | |
Height | 23.7mm | |
Interface | UART | |
Length | 43mm | |
Maximum Operating Supply Voltage | 5 V | |
Maximum Operating Temperature | +50 °C | |
Minimum Operating Temperature | -10 °C | |
Technology | Digital | |
Width | 36mm | |
Select all | ||
---|---|---|
Brand Honeywell | ||
Sensor Type Light | ||
Mounting Type Surface Mount | ||
Pin Count 8 | ||
Dimensions 43 x 36 x 23.7mm | ||
Height 23.7mm | ||
Interface UART | ||
Length 43mm | ||
Maximum Operating Supply Voltage 5 V | ||
Maximum Operating Temperature +50 °C | ||
Minimum Operating Temperature -10 °C | ||
Technology Digital | ||
Width 36mm | ||
- COO (Country of Origin):
- CN
The Honeywell HPM Series Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the concentration range of 0 μg/m3 to 1,000 μg/m3 in a given environment. A laser light source illuminates a particle as it is pulled through the detection chamber. As particles pass through the laser beam, the light source becomes obscured and is recorded on the photo or light detector.
Laser-based light scattering particle sensing
Concentration range: 0 μg/m3 to 1,000 μg/m3
Fully calibrated
EMC: Heavy industrial level IEC61000
Response time: <6 s
Supply current: 80 mA max.
Output signal: UART (Universal Asynchronous Receiver/Transmitter)
PM2.5 output (PM10 output optional)
RoHS compliant
REACH compliant.
Concentration range: 0 μg/m3 to 1,000 μg/m3
Fully calibrated
EMC: Heavy industrial level IEC61000
Response time: <6 s
Supply current: 80 mA max.
Output signal: UART (Universal Asynchronous Receiver/Transmitter)
PM2.5 output (PM10 output optional)
RoHS compliant
REACH compliant.