Belden 9841 Series Multipair Cable, 1 Pairs, 2 Cores, 0.2 mm², Screened, 24 AWG, 152m, Screened Shield, RS-485 Cable
- RS Stock No.:
- 331-8893
- Distrelec Article No.:
- 304-10-133
- Mfr. Part No.:
- 9841.01152
- Brand:
- Belden
Subtotal (1 reel of 152 metres)*
£991.54
(exc. VAT)
£1,189.85
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 11 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
---|---|---|
1 + | £991.54 | £6.523 |
*price indicative
- RS Stock No.:
- 331-8893
- Distrelec Article No.:
- 304-10-133
- Mfr. Part No.:
- 9841.01152
- Brand:
- Belden
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Belden | |
Number of Pairs | 1 | |
Cross Sectional Area | 0.2 mm² | |
Number of Cores | 2 | |
American Wire Gauge | 24 AWG | |
Screened/Unscreened | Screened | |
Length | 152m | |
Shield Type | Tinned Copper Braid | |
Sheath Colour | Chrome | |
CPR Certification | Eca | |
Cable Type | RS-485 | |
Outer Diameter | 5.9mm | |
Outer Sheath Material | PVC | |
Characteristic Impedance | 120 Ω | |
Voltage Rating | 300 V | |
Minimum Operating Temperature | -30°C | |
Maximum Operating Temperature | +80°C | |
Core Strands | 7/0.20 mm | |
Fire Behaviour | Flame Retardant | |
Series | 9841 | |
Shielded/Unshielded | Shielded | |
Standards Met | Euroclass Eca | |
Select all | ||
---|---|---|
Brand Belden | ||
Number of Pairs 1 | ||
Cross Sectional Area 0.2 mm² | ||
Number of Cores 2 | ||
American Wire Gauge 24 AWG | ||
Screened/Unscreened Screened | ||
Length 152m | ||
Shield Type Tinned Copper Braid | ||
Sheath Colour Chrome | ||
CPR Certification Eca | ||
Cable Type RS-485 | ||
Outer Diameter 5.9mm | ||
Outer Sheath Material PVC | ||
Characteristic Impedance 120 Ω | ||
Voltage Rating 300 V | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature +80°C | ||
Core Strands 7/0.20 mm | ||
Fire Behaviour Flame Retardant | ||
Series 9841 | ||
Shielded/Unshielded Shielded | ||
Standards Met Euroclass Eca | ||
- COO (Country of Origin):
- NL
Belden 9841 Series Multipair Cable, 152m Length, 2 Cores - 9841.01152
This multipair cable is designed for industrial communication applications, specifically tailored for RS-485 systems. Featuring an overall length of 152m, it consists of a single pair of 24 AWG conductors made of tinned copper, encased in a flame-retardant PVC sheath. The cable boasts excellent shielding through tinned copper braid and is compliant with Eca CPR standards, suitable for a variety of demanding environments.
Features & Benefits
• Screened design minimises electromagnetic interference
• Flame retardant construction enhances safety in installations
• Tinned copper braid provides superior signal integrity
• PVC sheath ensures durability in various settings
• 300V voltage rating supports robust performance
• Operating temperature range from -30 °C to +80 °C
• Flame retardant construction enhances safety in installations
• Tinned copper braid provides superior signal integrity
• PVC sheath ensures durability in various settings
• 300V voltage rating supports robust performance
• Operating temperature range from -30 °C to +80 °C
Applications
• Utilised for point-of-sale systems to ensure stable connections
• Employed in computer communications for reliable data transmission
• Ideal for low voltage analogue and digital control systems
• Suitable for panel wiring in industrial environments
• Tasks include interfacing with PLCs, VFDs, and SCADA systems
• Employed in computer communications for reliable data transmission
• Ideal for low voltage analogue and digital control systems
• Suitable for panel wiring in industrial environments
• Tasks include interfacing with PLCs, VFDs, and SCADA systems
How does the cable maintain performance over long distances?
The cable features a characteristic impedance of 120 Ω, optimised for RS-485 communication, ensuring minimal signal loss even over extended runs. This is crucial for maintaining data integrity between devices situated far apart in industrial settings.
What kind of environments is this cable designed for?
The multipair cable is intended for indoor use, capable of withstanding operational conditions ranging from -30 °C up to +80 °C. Its flame-retardant attributes contribute to safety in potentially hazardous locations.
What installation considerations should be taken into account?
When installing, maintain a minimum bend radius of 2.5 in (64 mm) to avoid damaging the cable structure. Adhere to the maximum pull tension of 72.3 lbs (32.8 kg) to ensure longevity and prevent failure during setup.
What types of signals can this cable handle effectively?
This cable is adept at transmitting low voltage analogue signals, such as 4-20mA and 0-10V, as well as low voltage digital control signals, making it versatile for various automation tasks and applications.
What shielding does this cable employ to ensure data integrity?
The multipair cable uses an effective combination of Beldfoil and tinned copper braid that offers 100% coverage, providing exceptional protection against electromagnetic interference (EMI) for reliable communication.