Jumo Capillary Thermostat, 150 °C Max, Automatic Reset, 10 A, Surface Mount

Subtotal (1 unit)*

£365.24

(exc. VAT)

£438.29

(inc. VAT)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 25 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£365.24

*price indicative

RS Stock No.:
278-776
Mfr. Part No.:
603021/70-1-531-00-0-00-30-13-20-150-8-6 000
Brand:
Jumo
Find similar products by selecting one or more attributes.
Select all

Brand

Jumo

Product Type

Thermostat

Minimum Operating Temperature

30°C

Maximum Operating Temperature

150°C

Thermostat Type

Capillary

Contact AC Voltage

230V ac

Contact Current

10A

Series

603021

Standards/Approvals

RoHS, GDRL, EAC, DIN EN 14597

Hazardous Area Certification

No

Mount Type

Surface Mount

Reset Type

Automatic

COO (Country of Origin):
DE
The Jumo 1 Pole Mechanical Surface Mounting Thermostat is very robust and can also be used in rough conditions. The measuring system used operates on the fluid expansion principle and can be used without any problems up to a maximum permissible probe temperature of 230°C.The protection tube made of high quality stainless steel (material no. 1.4571) has a diameter of 8 mm and is fixed with a thread G 1/2 form A according to DIN 3852/2. The electrical connection is made directly to the installed microswitch via screw terminals, which can directly switch a maximum permissible switching capacity of AC 230 V / 10 A. The safety temperature limiter can be used very flexibly and is used in heating, air conditioning and ventilation technology as well as in the plastics industry, in apparatus and mechanical engineering and in furnace construction, in district heating transfer stations and for temperature monitoring in laboratories and climatic chambers.

Shock resistant case with high quality plastic cover

Aluminium die cast lower part

Approved according to DIN EN 14597 and an EAC approval

Max ambient temperature at switch head (IP54) is 80°C

switch off temperature set with a screwdriver after removing case lid

Circuit opens and microswitch locks if temp exceeds limit

Micro switch can be manually unlocked once temp falls below 10% of scale range

STB accuracy is +0/-5% in upper third of scale

Neutral switching contact when the system is damaged

Circuit opens below -20°C and can be unlocked by restart button above -20°C

No auxiliary energy needed for temperature measurement