Phoenix Contact, LIT 1X2-24 Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
- RS Stock No.:
- 802-6678
- Distrelec Article No.:
- 304-02-022
- Mfr. Part No.:
- 2804610
- Brand:
- Phoenix Contact
Bulk discount available
Subtotal (1 unit)*
£62.53
(exc. VAT)
£75.04
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 33 unit(s) ready to ship
- Plus 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 - 4 | £62.53 |
5 - 9 | £60.03 |
10 - 24 | £56.90 |
25 + | £51.90 |
*price indicative
- RS Stock No.:
- 802-6678
- Distrelec Article No.:
- 304-02-022
- Mfr. Part No.:
- 2804610
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Phoenix Contact | |
Suppressor Type | Surge Arrester Protection Module | |
Maximum Voltage Rating | 24 V dc | |
Mounting Type | DIN Rail | |
Maximum Surge Current | 20kA | |
Series | LIT 1X2-24 | |
Length | 93.1mm | |
Depth | 6.2mm | |
Height | 102.5mm | |
Dimensions | 93.1 x 6.2 x 102.5mm | |
Lead Pitch | 6.2mm | |
Minimum Operating Temperature | -40°C | |
Maximum Operating Temperature | +80°C | |
Model | LIT 1X2-24 | |
Select all | ||
---|---|---|
Brand Phoenix Contact | ||
Suppressor Type Surge Arrester Protection Module | ||
Maximum Voltage Rating 24 V dc | ||
Mounting Type DIN Rail | ||
Maximum Surge Current 20kA | ||
Series LIT 1X2-24 | ||
Length 93.1mm | ||
Depth 6.2mm | ||
Height 102.5mm | ||
Dimensions 93.1 x 6.2 x 102.5mm | ||
Lead Pitch 6.2mm | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature +80°C | ||
Model LIT 1X2-24 | ||
- COO (Country of Origin):
- DE
Phoenix Contact LIT 1X2-24 Series Surge Protector, 24V DC Maximum Voltage Rating, 20kA Maximum Surge Current - 2804610
This surge protector is designed for effective surge arrester protection in various applications, featuring a compact DIN rail mount. With a maximum voltage rating of 24V DC, the surge protection device is tailored for one floating signal circuit in 2-conductor technology. Its dimensions of 93.m x 6.2mm x 102.5mm allow it to save valuable space in your electrical setups.
Features & Benefits
• Compact design optimises space with a width of only 6.2mm for efficient use of space
• Achieves high surge current protection protects up to 20kA, ensuring reliable equipment safety
• Operates effectively in a temperature range of -40°C to +80°C guarantees reliability across a wide temperature range
• Easy installation on a standard 35mm DIN rail for quick and straightforward setup
• Designed to support HART communications enables seamless integration with control systems for efficient operation
• Achieves high surge current protection protects up to 20kA, ensuring reliable equipment safety
• Operates effectively in a temperature range of -40°C to +80°C guarantees reliability across a wide temperature range
• Easy installation on a standard 35mm DIN rail for quick and straightforward setup
• Designed to support HART communications enables seamless integration with control systems for efficient operation
Applications
• Ideal for use in automation and control systems
• Suitable for electrical circuits requiring high protection levels
• Employed in industrial environments for machinery and equipment
• Used for protecting sensitive electronics against voltage spikes
• Suitable for electrical circuits requiring high protection levels
• Employed in industrial environments for machinery and equipment
• Used for protecting sensitive electronics against voltage spikes
How does this device ensure effective surge suppression in demanding environments?
It features a robust construction with an overvoltage category of III and a pollution degree of 2, ensuring reliability in challenging conditions.
What kind of connections can be used with this surge protection module?
The device accommodates screw connections with a conductor cross-section ranging from 0.2mm² to 2.5mm² for both flexible and rigid conductors.
What are the key performance metrics regarding surge currents?
It can handle maximum discharge currents of 10 kA in both line-line and line-earth configurations, ensuring outstanding protection against transient voltage spikes.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Related links
- Phoenix Contact, S-PT-EX-24DC-1/2 Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Surge
- Phoenix Contact, PT-IQ-2X1-24DC-UT Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Protective
- Dehn 33 V dc Maximum Voltage Rating 20kA Maximum Surge Current Type 2 Arrester
- Series xPole Surge Protector 385 V Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
- Eaton, Series xPole Surge Protector 460 V Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
- Series xPole Surge Protector 280 V Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
- Eaton, Series xPole Surge Protector 335 V Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
- Eaton, Series xPole Surge Protector 280 V Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester