Endress+Hauser Single Phase Surge Arrester, 9kA, 550V (Volts), DIN Rail Mount
- RS Stock No.:
- 288-6485
- Mfr. Part No.:
- HAW562-AAD
- Brand:
- Endress+Hauser
Subtotal (1 unit)*
£119.42
(exc. VAT)
£143.30
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 6 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £119.42 |
*price indicative
- RS Stock No.:
- 288-6485
- Mfr. Part No.:
- HAW562-AAD
- Brand:
- Endress+Hauser
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Endress+Hauser | |
Device Type | Surge Arrestor | |
Voltage Protection Rating | 550V (Volts) | |
Maximum Surge Current | 9kA | |
Series | HAW562 | |
Electrical Phase | Single | |
Mounting Style | DIN Rail Mount | |
Select all | ||
---|---|---|
Brand Endress+Hauser | ||
Device Type Surge Arrestor | ||
Voltage Protection Rating 550V (Volts) | ||
Maximum Surge Current 9kA | ||
Series HAW562 | ||
Electrical Phase Single | ||
Mounting Style DIN Rail Mount | ||
- COO (Country of Origin):
- DE
The Endress+Hauser HAW562 surge arrester for DIN rail is used to protect electronic components from being destroyed by overvoltage. It ensures that overvoltage surges which occur in signal cables (e.g. 4 to 20 mA), in communication lines (fieldbuses) and in power lines are safely passed into the ground. The functionality of the transmitter or the electronics component to be protected is not affected. Surge arresters are used to weaken residual currents from upstream lightning protection steps and to limit system-induced or -generated overvoltage surges.
Protects electronic components from being destroyed by overvoltage
Weakens residual currents from upstream lightning protection steps and limits system-induced or -generated overvoltage surges
Overvoltage surges are safely passed into the ground
The fu
Weakens residual currents from upstream lightning protection steps and limits system-induced or -generated overvoltage surges
Overvoltage surges are safely passed into the ground
The fu
Related links
- Endress+Hauser Single Phase Surge Arrester 600V (Volts), DIN Rail Mount
- Endress+Hauser Single Phase Surge Arrester 400V (Volts) Panel Mount Mount
- Endress+Hauser Single Phase Surge Arrester 1250V (Volts) Panel Mount Mount
- Endress+Hauser Surge Arrester 230V (Volts), DIN Rail Mount
- Endress+Hauser Single Phase Surge Arrester 650V (Volts), Screw Mount Mount
- Endress+Hauser Single Phase Surge Arrester 1100V (Volts), Screw Mount Mount
- Endress+Hauser Single Phase Surge Arrester 900V (Volts), Screw Mount Mount
- Endress+Hauser Single Phase Surge Arrester, Screw Mount Mount