Sensata / Crydom Solid State Relay, 50 A rms Load, Panel Mount, 280 V rms Load, 32 V Control
- RS Stock No.:
- 480-627
- Mfr. Part No.:
- MCBC2450AF
- Brand:
- Sensata / Crydom
Image representative of range
Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
- RS Stock No.:
- 480-627
- Mfr. Part No.:
- MCBC2450AF
- Brand:
- Sensata / Crydom
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Sensata / Crydom | |
Maximum Load Current | 50 A rms | |
Mounting Type | Panel Mount | |
Maximum Load Voltage | 280 V rms | |
Maximum Control Voltage | 32 V | |
Switching Type | DC | |
Control Voltage Range | 8 → 32 V dc | |
Minimum Load Current | 150 mA | |
Load Voltage Range | 180 → 280V ac | |
Dimensions | 58.4 x 45.7 x 19.8mm | |
Maximum Operating Temperature | +80°C | |
Depth | 45.7mm | |
Height | 19.8mm | |
Minimum Operating Temperature | -20°C | |
Length | 58.4mm | |
Operating Temperature Range | -20 → +80°C | |
Select all | ||
---|---|---|
Brand Sensata / Crydom | ||
Maximum Load Current 50 A rms | ||
Mounting Type Panel Mount | ||
Maximum Load Voltage 280 V rms | ||
Maximum Control Voltage 32 V | ||
Switching Type DC | ||
Control Voltage Range 8 → 32 V dc | ||
Minimum Load Current 150 mA | ||
Load Voltage Range 180 → 280V ac | ||
Dimensions 58.4 x 45.7 x 19.8mm | ||
Maximum Operating Temperature +80°C | ||
Depth 45.7mm | ||
Height 19.8mm | ||
Minimum Operating Temperature -20°C | ||
Length 58.4mm | ||
Operating Temperature Range -20 → +80°C | ||
- COO (Country of Origin):
- MX
MCBC- Burst Fire Controller
This device regulates the speed of an on/off pulse. Provides a smooth proportional control that minimizes electrical noise by utilizing zero-cross detection and switching, firing only complete AC cycles. Specialized Phase Detection Circuitry allows the MCBC to be connected to only one side of the load, minimizing installation wiring. Particularly suitable for use in heating applications where the electrical noise generated by typical phase angle controllers cannot be tolerated.
Burst Fire Controller / SSR in one package
Low Voltage, current or potentiometer control
Output status indicator (load open, no voltage)
0-100% Control Range
10 AC cycle time base period
Dielectric strength 50/60Hz, input/output/base: 4000Vrms
Separate output enable / disable control
SCR based output load switching
Internal snubber network included
Low Voltage, current or potentiometer control
Output status indicator (load open, no voltage)
0-100% Control Range
10 AC cycle time base period
Dielectric strength 50/60Hz, input/output/base: 4000Vrms
Separate output enable / disable control
SCR based output load switching
Internal snubber network included
Note
Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet
Proportional and Power
Note
Temperature can affect current rating; please consult the data sheet for potential derating.