Burkert Solenoid Valve 053188, 2 Port, NC, 230 V ac 1/4 in G, 6.35 mm

Subtotal (1 unit)*

£159.58

(exc. VAT)

£191.50

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 14 unit(s) ready to ship
  • Plus 5 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£159.58

*price indicative

RS Stock No.:
440-931
Mfr. Part No.:
053188
Brand:
Burkert
Find similar products by selecting one or more attributes.
Select all

Brand

Burkert

Product Type

Solenoid Valve

Supply Voltage

230 V ac

Number of Ports

2

Inlet Port Size

1/4 in G

Outlet Port Size

6.35 mm

Default Valve Position

NC

Outlet Connection Type

Threaded

Inlet Thread Standard

G

Inlet Connection Type

Threaded

Orifice Diameter

4mm

Inlet Port Gender

Female

Series

0255

Body Material

Brass

Application

Fuel, Hydraulic Oil, Steam, Water

Outlet Port Gender

Female

Outlet Thread Standard

G

Maximum Operating Pressure

12 bar

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

55°C

Servo Assist

Yes

Standards/Approvals

No

Hazardous Area Certification

No

Maximum Closing Time

30ms

Flow Factor Kv

0.5m³/h

Maximum Opening Time

20ms

COO (Country of Origin):
DE

Series 255 Two Way Normally Closed Solenoid Valves


For use with water, steam, air, gasses, hot oils and hydrocarbons, alkaline washing agents

Heat-resistant slip-over epoxy encapsulated coil

Brass body and PTFE Seal

Three-pin DIN connector rated to IP65 can be positioned 360° in 90° increments

Fluid temperature range to 180°C (130°C with fitted cable plug)

Ambient temperature +55°C maximum

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.