Burkert Solenoid Valve 089404, 2 port(s) , NC, 24 V dc, 1/2in

Subtotal (1 unit)*

£173.72

(exc. VAT)

£208.46

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 17 unit(s) ready to ship
  • Plus 69 unit(s) shipping from 06 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£173.72

*price indicative

RS Stock No.:
439-212
Mfr. Part No.:
089404
Brand:
Burkert
Find similar products by selecting one or more attributes.
Select all

Brand

Burkert

Supply Voltage

24 V dc

Number of Ports

2

Connection Size

1/2in

Connection

1/2 in G Female

Operation

Direct

Default Valve Position

NC

Suitable Applications

Alcohol, Fuel, Hydraulic Oil, Organic Solvent, Steam, Waste Gas, Water

Type

2/2

Orifice Diameter

4mm

Body Material

Brass

Series

0255

Maximum Working Pressure

4 bar

Operating Temperature Range

-40 → +55 °C

Connection Gender

Female

Thread Standard or Connection Type

G

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+55°C

Flow Factor Kv

0.5m³/h

Maximum Closing Time

30ms

Maximum Opening Time

80ms

COO (Country of Origin):
DE

Burkert Solenoid Valve


The Burkert 0255 series 1/2in G female solenoid valve has a supply voltage rating of 24VDC. This 2-port NC position valve is suitable for high pressure and high temperature. This direct-acting plunger solenoid valve has a heat-resistant slip-over epoxy encapsulated coil. The maximum opening and closing time of the valve is 20 milliseconds and 30 milliseconds. It is used with water, steam, air, gasses, hot oil, hydrocarbons and alkaline washing agents.
Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the operation of the valve when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3/2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2/2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Features and Benefits


Maximum working pressure is 4bar
3-pin DIN connector can be positioned 360° in 90° increments
Brass body and PTFE Seal
Flow factor (Kv) is 0.5m³/h
Operating temperature ranges between -40°C and 55°C
Power consumption ranges between 35VA and 40VA (inrush AC)
Push-over solenoid system

Certifications


IP65 rated

Related links