Dold Soft Starter, 1.5 kW, 230 V ac, 1 Phase, IP20, IP40
- RS Stock No.:
 - 327-7809
 - Mfr. Part No.:
 - IL9017 AC230V 1.5kW
 - Brand:
 - Dold
 
Subtotal (1 unit)*
£175.45
(exc. VAT)
£210.54
(inc. VAT)
Stock information currently inaccessible
Units  | Per unit  | 
|---|---|
| 1 + | £175.45 | 
*price indicative
- RS Stock No.:
 - 327-7809
 - Mfr. Part No.:
 - IL9017 AC230V 1.5kW
 - Brand:
 - Dold
 
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all  | Attribute | Value | 
|---|---|---|
| Brand | Dold | |
| Power Rating | 1.5 kW | |
| Motor Starter Type | Soft Start | |
| Voltage Rating | 230 V ac | |
| Phase | 1 | |
| Current Rating | 10 A | |
| IP Rating | IP20, IP40 | |
| Overall Length | 61mm | |
| Overall Width | 35mm | |
| Overall Depth | 90mm | |
| Select all | ||
|---|---|---|
Brand Dold  | ||
Power Rating 1.5 kW  | ||
Motor Starter Type Soft Start  | ||
Voltage Rating 230 V ac  | ||
Phase 1  | ||
Current Rating 10 A  | ||
IP Rating IP20, IP40  | ||
Overall Length 61mm  | ||
Overall Width 35mm  | ||
Overall Depth 90mm  | ||
- COO (Country of Origin):
 - DE
 
Soft starter for AC current drives, IL9017
Robust electronic control unit specially designed for the smooth start-up of single-phase asynchronous machines (AC current motors with auxiliary capacitor)
After starting, the power electronics are bridged via an internal relay contact to minimise losses in the device
Increases the service life of single-phase asynchronous motors and mechanical drive components
For 1.5 kW motor ratings
Start-up time and LED displays can be adjusted separately
35 mm overall width
After starting, the power electronics are bridged via an internal relay contact to minimise losses in the device
Increases the service life of single-phase asynchronous motors and mechanical drive components
For 1.5 kW motor ratings
Start-up time and LED displays can be adjusted separately
35 mm overall width
Warning
The IL9017 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.
In the decoupled state (without load), the starting behaviour is not particularly smooth.