Pilz PNOZ X PZE X4 Safety Relay 24V dc, Single Channel 4 Safety Contacts
- RS Stock No.:
- 362-0168
- Distrelec Article No.:
- 304-11-391
- Mfr. Part No.:
- 774585
- Brand:
- Pilz
Subtotal (1 unit)*
£136.21
(exc. VAT)
£163.45
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 17 unit(s) ready to ship
- Plus 15 unit(s) ready to ship from another location
- Plus 54 unit(s) shipping from 27 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £136.21 |
*price indicative
- RS Stock No.:
- 362-0168
- Distrelec Article No.:
- 304-11-391
- Mfr. Part No.:
- 774585
- Brand:
- Pilz
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Pilz | |
Supply Voltage | 24V dc | |
Number of Channels | 1 | |
Safety Contacts | 4 | |
Function | Expansion Module | |
Reset Method | Automatic | |
Range | PNOZ X | |
Safety Category ISO 13849-1 | 4 | |
PL ISO 13849-1 | e | |
SIL IEC 61508 | 3 | |
Terminal Type | Screw | |
Series | PZE X4 | |
Depth | 121mm | |
Width | 22.5mm | |
Performance Level | e | |
Length | 87mm | |
Select all | ||
---|---|---|
Brand Pilz | ||
Supply Voltage 24V dc | ||
Number of Channels 1 | ||
Safety Contacts 4 | ||
Function Expansion Module | ||
Reset Method Automatic | ||
Range PNOZ X | ||
Safety Category ISO 13849-1 4 | ||
PL ISO 13849-1 e | ||
SIL IEC 61508 3 | ||
Terminal Type Screw | ||
Series PZE X4 | ||
Depth 121mm | ||
Width 22.5mm | ||
Performance Level e | ||
Length 87mm | ||
- COO (Country of Origin):
- FR
PZE X4 24VDC 4n/o Safety Relay from PILZ
The PILZ PZE X4 is primarily used for increasing the number of contacts you can use between your safety related control devices such as E stops, safety gates and more. The reliability Safety Relay technology from PILZ means you can control your environment with confidence that the safety status is being monitored.
Features and benefits
Universal power supply, compatible with many different outlets of power sources
LED indicator for switching your channel status from 1 to 2 and also to monitor your supply voltage
Plug in terminal connections with either a spring loaded terminal or screw terminal giving you versatility in where your unit can be used.
Feedback loop monitoring come with all base units allowing you to monitor the safety loop and identify hazards before they happen.
Single or Dual channel input operation (Single channel are used more beneficially with smaller type machines where you need to use a dedicated logic device that only has a small function to cut off in an emergency – Dual allows you to take control of more safety circuits and control a greater amount of control zones at any given time)
LED indicator for switching your channel status from 1 to 2 and also to monitor your supply voltage
Plug in terminal connections with either a spring loaded terminal or screw terminal giving you versatility in where your unit can be used.
Feedback loop monitoring come with all base units allowing you to monitor the safety loop and identify hazards before they happen.
Single or Dual channel input operation (Single channel are used more beneficially with smaller type machines where you need to use a dedicated logic device that only has a small function to cut off in an emergency – Dual allows you to take control of more safety circuits and control a greater amount of control zones at any given time)
Safety features
Earth fault in the feedback loop can be detected depending on the base unit that is used
Earth faults in the input circuit can be detected as the output will de-energise the relays and open the safety contacts.
The device will retain its safety functions in any case of component failures ensuring your safety.
Any safety functions in your existing circuit can be easily transferred with this expansion module with ease.
Earth faults in the input circuit can be detected as the output will de-energise the relays and open the safety contacts.
The device will retain its safety functions in any case of component failures ensuring your safety.
Any safety functions in your existing circuit can be easily transferred with this expansion module with ease.
Applications
Guard systems
Emergency stop buttons
Pull wire emergency stop switches
Safety light curtains
Safety sensors
Technical safety parameters
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
EN 62061
EN ISO 13849-1
VDE 0113-1
Note
All base units must have a feedback control loop
Approvals
BG, UL listed for Canada and US
Approvals
BG, UL listed for Canada and US
Related links
- Pilz PNOZ X PZE X4V Safety Relay 24V dc, Single Channel 4 Safety Contacts
- Pilz PNOZ X PZE 9 1 Auxiliary Contacts Safety Relay 24V dc, Dual-Channel 8 Safety Contacts
- Pilz PNOZ X PNOZ X7 Safety Relay 24V ac/dc, Single Channel 2 Safety Contacts
- Pilz PNOZ X PNOZ X1 1 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 3 Safety Contacts
- Pilz PNOZ X PZA 30 2 Auxiliary Contacts Safety Relay 24V dc, Single Channel 1 Safety Contacts
- Pilz PNOZ X PNOZ XV1P Safety Relay 24V dc, Single/Dual-Channel 2 Safety Contacts
- Pilz PNOZ X PNOZ X5 Safety Relay 24V ac/dc, Single/Dual-Channel 2 Safety Contacts
- Pilz PNOZ X PNOZ X10 4 Auxiliary Contacts Safety Relay 24V dc, Single/Dual-Channel 6 Safety Contacts