SICK ReLy RLY3 2 Auxiliary Contacts Safety Relay 24V dc, Dual-Channel 2 Safety Contacts
- RS Stock No.:
- 285-4218
- Mfr. Part No.:
- RLY3-LOOP100
- Brand:
- SICK
Subtotal (1 unit)*
£292.31
(exc. VAT)
£350.77
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 999,999,999 unit(s) shipping from 02 January 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £292.31 |
*price indicative
- RS Stock No.:
- 285-4218
- Mfr. Part No.:
- RLY3-LOOP100
- Brand:
- SICK
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | SICK | |
Supply Voltage | 24V dc | |
Number of Channels | 2 | |
Safety Contacts | 2 | |
Function | Emergency Stop | |
Auxiliary Contacts | 2 | |
Reset Method | Automatic & Manual | |
Range | ReLy | |
Safety Category ISO 13849-1 | 4 | |
SIL IEC 61508 | 3 | |
Terminal Type | Spring Terminal | |
Configurable | Yes | |
Width | 18mm | |
Safety Category | 4 | |
Depth | 85.5mm | |
Series | RLY3 | |
Performance Level | e | |
Length | 124.6mm | |
Select all | ||
---|---|---|
Brand SICK | ||
Supply Voltage 24V dc | ||
Number of Channels 2 | ||
Safety Contacts 2 | ||
Function Emergency Stop | ||
Auxiliary Contacts 2 | ||
Reset Method Automatic & Manual | ||
Range ReLy | ||
Safety Category ISO 13849-1 4 | ||
SIL IEC 61508 3 | ||
Terminal Type Spring Terminal | ||
Configurable Yes | ||
Width 18mm | ||
Safety Category 4 | ||
Depth 85.5mm | ||
Series RLY3 | ||
Performance Level e | ||
Length 124.6mm | ||
- COO (Country of Origin):
- HU
Overview
High ease of use, more space in the control cabinet, quicker production starts, more compact machines with shorter safety distances and reduced downtime: With the clever ReLy safety relay, you get even more out of your application, and that with high safety at performance level e.
So dont rely on just any safety relay – use the ReLy from SICK. Thanks to clearly defined areas of application, selecting the right variant is simple as can be.
At a glance
Clever, User friendly housing functions
Thin design with construction widths from 18 mm
Fast response times of under 10 ms (depending on the type)
Status LEDs and diagnostic interfaces
Variants for universal application and for safe series connection with Flexi Loop available
Thin design with construction widths from 18 mm
Fast response times of under 10 ms (depending on the type)
Status LEDs and diagnostic interfaces
Variants for universal application and for safe series connection with Flexi Loop available
Your Benefit
Reduce commissioning work thanks to quick installation and wiring with a single front connector
Quick module exchange thanks to the simple one-click mounting rail release
Significant space savings in the control cabinet with a 20% thinner housing compared to the predecessor version
Design machines more compactly and benefit from faster processes thanks to short response times and reduced safety distances
Increase machine availability with comprehensive diagnostic options
Long service life even in highly dynamic processes with many switching cycles
Quick module exchange thanks to the simple one-click mounting rail release
Significant space savings in the control cabinet with a 20% thinner housing compared to the predecessor version
Design machines more compactly and benefit from faster processes thanks to short response times and reduced safety distances
Increase machine availability with comprehensive diagnostic options
Long service life even in highly dynamic processes with many switching cycles
Applications
Fields of applications
Monitoring of sensors with OSSD outputs, equivalent and complementary safety switches as well as two-hand control units
Integration of the Flexi Loop safe series connection
Stop category 1 applications with time-delayed switching of
Monitoring of sensors with OSSD outputs, equivalent and complementary safety switches as well as two-hand control units
Integration of the Flexi Loop safe series connection
Stop category 1 applications with time-delayed switching of