Better World
Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 48 → 240V ac/dc, Single
- RS Stock No.:
- 201-1468
- Mfr. Part No.:
- XPSUAB31CC
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£150.90
(exc. VAT)
£181.08
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- Plus 3 unit(s) shipping from 01 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £150.90 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 201-1468
- Mfr. Part No.:
- XPSUAB31CC
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Supply Voltage | 48 → 240V ac/dc | |
Number of Channels | 1 | |
Safety Contacts | 2 | |
Function | Emergency Stop | |
Auxiliary Contacts | 8 | |
Range | Harmony XPS/ Preventa XPS | |
Terminal Type | Spring | |
Depth | 120mm | |
Width | 22.5mm | |
Series | XPSU | |
Better World Verification | Green Premium | |
Better World Product | Yes | |
Length | 100mm | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Supply Voltage 48 → 240V ac/dc | ||
Number of Channels 1 | ||
Safety Contacts 2 | ||
Function Emergency Stop | ||
Auxiliary Contacts 8 | ||
Range Harmony XPS/ Preventa XPS | ||
Terminal Type Spring | ||
Depth 120mm | ||
Width 22.5mm | ||
Series XPSU | ||
Better World Verification Green Premium | ||
Better World Product Yes | ||
Length 100mm | ||
- COO (Country of Origin):
- ID
Schneider Electric Preventa Range of Safety Relays - XPS Universal Range
The XPSUAB range of safety relay modules are predominantly designed to monitor two-hand control stations, used in applications such as:
• Monitoring emergency stops
• Antivalent contacts
• Guard switches
• Magnetic switches
• Proximity safety switches
• PNP sensors
• RFID safety switches
• Safety light curtains
• Monitoring emergency stops
• Antivalent contacts
• Guard switches
• Magnetic switches
• Proximity safety switches
• PNP sensors
• RFID safety switches
• Safety light curtains
Safety relays with a clever design that allows the monitoring of dangerous operations, to initiate a dangerous movement both operators must be activated within an interval of 0.5 seconds which is referred to as synchronous activation. If one of the two pushbuttons is released during a dangerous operation, the control sequence is automatically cancelled. Users can resume the dangerous operation through both pushbuttons returning to their initial position and reactivating them within the required time interval.
Features & Benefits
• Automatic, manual and monitored starts
• Type 4 light curtains conforming to IEC 61496-1 which have solid-state safety outputs with test function
• These functions are selected, and the start function can be configured by selector switches on the front face.
• A solid-state diagnostic output with complete status information facilitates maintenance.
• 6 LEDs on the front face provide information on the monitoring circuit status
• 1 safety input
• 2 On/Off control outputs which are configurable pulsed
• 1 single safety changeover output
• Removable terminal blocks for the connection type
• Type 4 light curtains conforming to IEC 61496-1 which have solid-state safety outputs with test function
• These functions are selected, and the start function can be configured by selector switches on the front face.
• A solid-state diagnostic output with complete status information facilitates maintenance.
• 6 LEDs on the front face provide information on the monitoring circuit status
• 1 safety input
• 2 On/Off control outputs which are configurable pulsed
• 1 single safety changeover output
• Removable terminal blocks for the connection type
Schneider Electric Preventa Safety Module - XPSUAB31CC
• Safety module levels for the relay include: Can reach PL c/category 1 conforming to ISO 13849-1, Can reach SILCL 1 conforming to IEC 62061 and Can reach SIL 1 conforming to IEC 61508
• NC pair, PNP pair, Antivalent pair and OSSD pair electrical circuit type
• Forms part of the preventa safety automation range of products
• This relay has a rated supply voltage of 48...240 V AC/DC - 10...10 %
• The device has an internal and electronic input protection type
• Minimum output current : 10 mA for relay output
• Minimum output voltage : 15 V for relay output
• Ambient air temperature for operation : -25 to 55 °C
• NC pair, PNP pair, Antivalent pair and OSSD pair electrical circuit type
• Forms part of the preventa safety automation range of products
• This relay has a rated supply voltage of 48...240 V AC/DC - 10...10 %
• The device has an internal and electronic input protection type
• Minimum output current : 10 mA for relay output
• Minimum output voltage : 15 V for relay output
• Ambient air temperature for operation : -25 to 55 °C
Related links
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 48 → 240V ac/dc, Single
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 4 Auxiliary Contacts Safety Relay 48 → 240V ac/dc, Single
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 2 Safety
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 5 Safety
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 1 Safety
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 3 Safety
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, 3-Channel 7 Safety
- Schneider Electric Harmony XPS/ Preventa XPS XPSU 4 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 5 Safety