Wieland SNA 4043K 115 120 V ac Safety Relay Dual Channel With 3 Safety Contacts

  • RS Stock No. 122-2491
  • Mfr. Part No. R1.188.1830.0
  • Brand Wieland
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

SNA 4043K Safety Relay for all Devices including Elevators and Heaters

Stop-Category 0 acc. EN 60204-1
Applications up to Category 4 acc. EN 954-1 or to SIL 3 respectively according to EN 62061 and PL e accoring to EN13849-1
Can be used as emergency stop and safety gate monitor
Each unit offers manual or automatic reset and cross monitoring
One or two-channel wiring
External device monitoring (EDM)
LED indication

Approvals

TUV, cULus

Specifications
Attribute Value
Supply Voltage 115 120 V ac
Number of Channels 2
Auxiliary Contacts 1
Function Elevator System, Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 3
Range SafeRELAY
Reset Method Manual
Terminal Type Screw
Standards Met CCC, CPT, CULus, EN 50156-1, EN 61511, EN 62061, EN 81-1, EN ISO 13849-1, FS, GL, GOST R, TUV
Length 22.5mm
Depth 96.5mm
Width 114mm
2 In stock for FREE next working day delivery
Price Each
£ 156.82
(exc. VAT)
£ 188.18
(inc. VAT)
Units
Per unit
1 +
£156.82
Related Products
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signalling Monitored start button feature Delay time: 0 – 30 s. adjustable in 12 steps by ...
The Bernstein AG 2NO 24VDC SCR relay is ...
Description:
The Bernstein AG 2NO 24VDC SCR relay is housed in a slim-line DIN rail polyamide material housing. The SCR relay is used to monitor the correct position and reliable operation of inputs from the safety sensors or safety switch contacts. • Compact in dimension 22.5mmx114.5mmx99mm• Feedback loop with monitored/automatic reset• ...
Safety category 4 in accordance with DIN EN ...
Description:
Safety category 4 in accordance with DIN EN 954Output: 2 N/Os, 1 N/C1 or 2-channel configuration Line termination detection on the ON button Programmable: Activation via the ON button or automatic ON function when the operating voltage is applied Programmable: With / without cross-fault detection in the emergency stop-control loop ...
Can be connected in four different input wiring ...
Description:
Can be connected in four different input wiring configurations: 1 N/C, 2N/C, or 2 PNP connections from a light curtain2 N/O immediate safety rated outputs, 2 N/O delayed safety outputs and 1 N/C delayed safety output Stop category 0 and 1Light curtain, E-stop, Safety Gate inputs Cross fault monitoring Monitored ...