PNOZmulti 2 PNOZ m ES Powerlink Communication Module, 24 V dc
- RS Stock No.:
- 918-6642
- Mfr. Part No.:
- 772119
- Brand:
- Pilz
Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
- RS Stock No.:
- 918-6642
- Mfr. Part No.:
- 772119
- Brand:
- Pilz
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Pilz | |
Range | PNOZmulti 2 | |
Series | PNOZ m ES | |
Type | Communication Module | |
For Use With | PNOZmulti 2 | |
Supply Voltage | 24 V dc | |
Mounting Style | DIN Rail | |
Dimensions | 101.4 x 22.5 x 110.4 mm | |
Select all | ||
---|---|---|
Brand Pilz | ||
Range PNOZmulti 2 | ||
Series PNOZ m ES | ||
Type Communication Module | ||
For Use With PNOZmulti 2 | ||
Supply Voltage 24 V dc | ||
Mounting Style DIN Rail | ||
Dimensions 101.4 x 22.5 x 110.4 mm | ||
- COO (Country of Origin):
- DE
PNOZmulti 2 Communication/Fieldbus Module Powerlink
The PNOZ m ES Powerlink expansion module connects to a base unit from the PNOZmulti 2 configurable control system.
Features and Benefits
Can be configured in the PNOZmulti Configurator
Connection for Ethernet POWERLINK (Ethernet POWERLINK V 2 protocol)
Station addresses from 1 ... 239, selected via rotary switch
The minimum cycle time for an application of 32 B Output and 32 B Input is275μs
The minimum cycle time is 500 μs at the maximum PDO size of 254 B Input and 32 B Output
128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus Ethernet POWERLINK
Maximum 1 PNOZ m ES Powerlink can be connected to the base unit
Transmission rate: 100 Mbps
Connection to fieldbus via RJ45 connector
Connection for Ethernet POWERLINK (Ethernet POWERLINK V 2 protocol)
Station addresses from 1 ... 239, selected via rotary switch
The minimum cycle time for an application of 32 B Output and 32 B Input is275μs
The minimum cycle time is 500 μs at the maximum PDO size of 254 B Input and 32 B Output
128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus Ethernet POWERLINK
Maximum 1 PNOZ m ES Powerlink can be connected to the base unit
Transmission rate: 100 Mbps
Connection to fieldbus via RJ45 connector
Approvals
CE, cULus Listed, TÜV, BG, CCC.
Supplied with
Screw terminals.
Related links
- Pilz PNOZ m ES Series Safety Module, 24 V dc
- Pilz PNOZmulti 2 PNOZ m BO Series Safety Controller 4 Safety Outputs, 24 V dc
- Pilz PNOZ m EF Series Input Module, 24 V dc
- Siemens Profibus Communication Module, 24 V
- Pilz 772138 Series Profinet Communication Module, 24 V dc
- Schneider Electric TeSyS LT Series Profibus Communication Module, 24 V
- Pilz 772137 Series Ethernet IP Communication Module, 24 V dc
- Schneider Electric Preventa Series Profibus Communication Module, 24 V