Product Details

PNOZsigma series contact extension blocks

Extension modules for PNOZ sigma series safety blocks.
The extension blocks provide reinforcement and increase the number of safety contacts on a base device.
The contact extension block expands an existing electrical circuit. Safety is still guaranteed, even if a component fails.
Removable terminals with connection via spring terminals.
DIN rail mounting.

Standards

EN 60947-5-1, EN 60204-1 VDE 0113-1

Specifications
Attribute Value
Series PNOZsigma
Type Output Module
For Use With PNOZ
Supply Voltage 24 V dc
Normal State Configuration 4NO/1NC
Number of Outputs 5
Power Rating 2 W
Mounting Style DIN Rail
Dimensions 98 x 17.5 x 120 mm
Terminal Type Screw
16 In stock for FREE next working day delivery
Price Each
£ 109.45
(exc. VAT)
£ 131.34
(inc. VAT)
Units
Per unit
1 +
£109.45
Related Products
The PSR safety relay extension units are for ...
Description:
The PSR safety relay extension units are for contact expansion. Single and two-channel control (stock no. 768-5147 & 801-5937), with one-channel connection only (stock no. 666-7113 & 801-5934)5 enabling current paths, 1 signalling current path, and 1 confirmation current pathInput voltage 24 Vac/dcOption of basic insulation or reinforced insulation.
Functions include muting and override, concurrence monitoring, monitoring ...
Description:
Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches. 2 or 4 muting sensors1 reset/restart input and external device monitoringActivation and time adjustable 0.33 to 60 minType of output safety capable outputs: ...
Fit for signal evaluation of outputs of safety ...
Description:
Fit for signal evaluation of outputs of safety magnetic switches2 safety contacts, Stop Category 06 Signalling outputsMulti-evaluation of up to 6 safety guardsSuitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks.
Easily add 4 N.C. instantaneous (EM) or delayed ...
Description:
Easily add 4 N.C. instantaneous (EM) or delayed (EMD) outputs to a systemSingle wire safe connection expands system without using any outputs of base moduleSelf-monitoring outputsTime delay configured from 0-300 sTimer functions include: on delay, off delay and joggingCan replace the following Guardmaster safety relays: MSR132E, MSR132ED.