SICK i110 Safety Interlock Switch, Die Cast Zinc

Subtotal (1 unit)*

£86.47

(exc. VAT)

£103.76

(inc. VAT)

Add to Basket
Select or type quantity
Limited stock
  • 11 left, ready to ship
  • Plus 5 left, ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£86.47

*price indicative

RS Stock No.:
285-9579
Mfr. Part No.:
i110-SA223
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2 NC, 2 NO

Housing Material

Die Cast Zinc

Series

i110

Contact AC Voltage

240V ac

IP Rating

IP67

Switch Contact Current

3A

Contact DC Voltage

24V dc

Minimum Operating Temperature

-20°C

Hazardous Area Certification

No

Maximum Operating Temperature

80°C

Width

43mm

Standards/Approvals

IEC 60529

Length

116.5mm

Depth

40mm

Number of Head Directions

5

COO (Country of Origin):
DO

SICK i110 Series Safety Interlock Switch, 3A Switch Contact Current, IP67 - i110-SA223


This safety interlock switch is an electro-mechanical device designed to protect access points by monitoring guard position and interrupting circuits when required. Built with a die-cast zinc housing and a slow-action switching element, it is intended for industrial automation contexts where environmental sealing and clear contact behaviour are needed. The unit connects via a single M20 cable gland and relies on external safety logic for fault detection.

Features and Benefits:


• 2NC 2NO safety contacts provide defined circuit separation for safety
• 240V AC rated contact voltage supports typical control systems
• 24V DC switching capability suits low-voltage safety circuits
• IP67 enclosure rating permits use in harsh environments
• Operates up to +80°C for high-temperature applications

Applications


• Suitable for guarding on production machinery
• Ideal for integration into conveyor access controls
• Used with safety PLCs for monitored interlock circuits
• Can be used for door monitoring in washdown areas
• Useful where actuator is supplied separately by the integrator

What is the connection method and conductor size?


It uses one M20 cable gland and accepts conductors up to 1.5mm².

How does the device behave if an internal fault occurs?


It has no internal fault detection so the connected safety logic must perform fault monitoring.

What mechanical lifetime and operating duty can be expected?


Mechanical life is 1x10⁶ switching cycles and actuation frequency is up to 7,200/h.

Are actuators included with delivery?


No actuator is supplied

the actuator must be provided separately.

What insulation and short-circuit characteristics are specified?


Rated insulation voltage is 240V, impulse withstand voltage is 2,500V and short-circuit protection is T10/10A.