Telemecanique Sensors XY2CE Safety Interlock Switch, 1NC/1NO, Zinc Alloy
- RS Stock No.:
- 130-0881
- Mfr. Part No.:
- XY2CE4A010
- Brand:
- Telemecanique Sensors
Subtotal (1 unit)*
£260.08
(exc. VAT)
£312.10
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 10 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £260.08 |
*price indicative
- RS Stock No.:
- 130-0881
- Mfr. Part No.:
- XY2CE4A010
- Brand:
- Telemecanique Sensors
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Telemecanique Sensors | |
Normal State Configuration | 1NC/1NO | |
Maximum AC Voltage | 240V | |
Maximum DC Voltage | 250V | |
Housing Material | Zinc Alloy | |
Range | Preventa XY2 | |
IP Rating | IP66 | |
Series | XY2CE | |
Maximum Current | (ac) 3 A, (dc) 270mA | |
Standards Met | CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508 | |
Depth | 142mm | |
Maximum Operating Temperature | +70°C | |
Minimum Operating Temperature | -25°C | |
Length | 229mm | |
Width | 105mm | |
Select all | ||
---|---|---|
Brand Telemecanique Sensors | ||
Normal State Configuration 1NC/1NO | ||
Maximum AC Voltage 240V | ||
Maximum DC Voltage 250V | ||
Housing Material Zinc Alloy | ||
Range Preventa XY2 | ||
IP Rating IP66 | ||
Series XY2CE | ||
Maximum Current (ac) 3 A, (dc) 270mA | ||
Standards Met CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508 | ||
Depth 142mm | ||
Maximum Operating Temperature +70°C | ||
Minimum Operating Temperature -25°C | ||
Length 229mm | ||
Width 105mm | ||
RoHS Status: Exempt
Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.
Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)
Note
The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.
Standards
EN/ISO 13850:2006
Related links
- Telemecanique Sensors ZCP Series Limit Switch IP66 Zinc Alloy Housing, 10A Max
- Telemecanique Sensors XCKJ Series Plunger Limit Switch IP66 Zinc Alloy Housing, 10A Max
- Telemecanique Sensors XCR Series Rod Limit Switch IP65 Zinc Alloy Housing, 500V ac Max
- Telemecanique Sensors XCR Series Roller Lever Limit Switch IP65 Zinc Alloy Housing, 500V ac
- Telemecanique Sensors XCMD Series Roller Plunger Limit Switch IP66 IP68 Zinc Alloy Housing
- Telemecanique Sensors XCMD Series Roller Plunger Limit Switch IP66 IP68 Zinc Alloy Housing,
- Telemecanique Sensors XCKD Series Roller Lever Limit Switch IP66 Zinc Alloy Housing, 10A Max
- Telemecanique Sensors XCKM Series Roller Lever Plunger Limit Switch IP66 Zinc Alloy Housing, 500V ac