Jumo 403025 Series Pressure Transmitter, 0bar Min, 4bar Max, Analogue Output, Differential Reading
- RS Stock No.:
- 279-664
- Mfr. Part No.:
- 403025/0-1-1-36-20-1-1-491-410-504-1-20-01 000
- Brand:
- Jumo
Subtotal (1 unit)*
£926.39
(exc. VAT)
£1,111.67
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 03 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £926.39 |
*price indicative
- RS Stock No.:
- 279-664
- Mfr. Part No.:
- 403025/0-1-1-36-20-1-1-491-410-504-1-20-01 000
- Brand:
- Jumo
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Jumo | |
Pressure Reading Type | Differential | |
Minimum Pressure Reading | 0bar | |
Maximum Pressure Reading | 4bar | |
Accuracy | 0.08 % | |
Output Type | Analogue | |
Series | 403025 | |
Select all | ||
---|---|---|
Brand Jumo | ||
Pressure Reading Type Differential | ||
Minimum Pressure Reading 0bar | ||
Maximum Pressure Reading 4bar | ||
Accuracy 0.08 % | ||
Output Type Analogue | ||
Series 403025 | ||
- COO (Country of Origin):
- DE
The Jumo dTRANS p20 pressure transmitter with HART interface combines maximum precision with simple operation. It is used to measure the relative pressure and absolute pressure of gases, vapors, and liquids. Pressure separators can also be connected for particular process technology applications (see types 409772 to 409784). The transmitter is programmable. As a result it is readily adaptable to a variety of different measurement tasks. A convenient setup program is available as an accessory to enable operation via the interfaces. For version for differential pressure, see type 403022. The cover is made of plastic. The electrical connection is via a round connector M12x1. The device has a nominal measuring range of 0...4 bar absolute pressure and an 4...20 mA 2 wire output with HART protocol. The process connection is a G1/2 to DIN EN 837 in stainless steel. The measuring temperature must be less than 120°C. The measuring system is filled with silicon oil.
Explosion protection Ex ia according to ATEX and EAC
Simple operation with rotary knob
Setup program
LCD display with bar graph
Display scaling with a choice of measuring units
Display of sensor temperature
Display of minimum and maximum pressures
Stainless steel case
For version with explosion protection Ex d see type 403026
Simple operation with rotary knob
Setup program
LCD display with bar graph
Display scaling with a choice of measuring units
Display of sensor temperature
Display of minimum and maximum pressures
Stainless steel case
For version with explosion protection Ex d see type 403026