18V ac 2 Output Through Hole PCB Transformer, 6VA

  • RS Stock No. 161-7825
  • Mfr. Part No. FL 6/18
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

//media.rs-online.com/t_line/L201683-01.gif
Specifications
Attribute Value
Secondary Voltage Rating 18V ac
Power Rating 6VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 53mm
Width 22.6mm
Depth 44mm
Dimensions 53 x 22.6 x 44mm
Weight 175g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
35 In stock for FREE next working day delivery
Price Each (In a Tray of 35)
£ 7.722
(exc. VAT)
£ 9.266
(inc. VAT)
Units
Per unit
Per Tray*
35 +
£7.722
£270.27
*price indicative
Related Products
Miniature PCB mounting audio frequency transformers suitable for ...
Description:
Miniature PCB mounting audio frequency transformers suitable for isolating and impedance matching applications.,The open types are mounted by means of a clamp with spade feet which may be bent over when securing to a PCB. The enclosed type is fully encapsulated in a glass filled nylon case. Z1606 is encapsulated. ...
From OEP, a range of high performance, industry ...
Description:
From OEP, a range of high performance, industry standard PCB mounting audio frequency transformers. The dual primary and secondary windings of these frequency transformers provide a wide range of impedance matching ratios to suit many input, interstage and output applications. • Industry standard 0•1in. grid spacing• Resin encapsulated in glass ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
MYRRA encapsulated electronic transformers are Switched Mode Power ...
Description:
MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology They are an interesting alternative to the traditional supply in the most common applications of power lower than 5WENERGY SAVING due to high efficiency and low standby power The applications for the Electronic serie are, telecom supplies, ...