6V ac 2 Output Through Hole PCB Transformer, 3VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

230 Vac Primary Transformers

Fully shrouded bobbins
Extra pins for secure board mounting
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
Input Voltage 230 Vac
//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 6V ac
Power Rating 3VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 38mm
Width 35mm
Depth 30mm
Dimensions 38 x 35 x 30mm
Weight 140g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
62 In stock for FREE next working day delivery
Price Each
£ 5.29
(exc. VAT)
£ 6.35
(inc. VAT)
Units
Per unit
1 - 9
£5.29
10 - 24
£4.86
25 +
£4.56
Related Products
Multi-tapped secondary winding. Suitable for a wide range ...
Description:
Multi-tapped secondary winding. Suitable for a wide range of applications requiring selected secondary voltages. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Multi-hole frame fixing Solder tag terminations100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation Fully shrouded bobbins100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...