9V ac 2 Output Through Hole PCB Transformer, 3VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

PCB Mount 115/230Vac Transformer

Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation
Fully shrouded bobbins
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
//media.rs-online.com/t_line/L231852-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 3VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 38mm
Width 35mm
Depth 30mm
Dimensions 38 x 35 x 30mm
Weight 140g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
14 In stock for FREE next working day delivery
Price Each
£ 7.97
(exc. VAT)
£ 9.56
(inc. VAT)
Units
Per unit
1 - 9
£7.97
10 - 24
£7.14
25 +
£6.65
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Two hole fixing wrap-over ...
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applications.ABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features ...
Brought to you by Block, this range of ...
Description:
Brought to you by Block, this range of Safety Isolating Transformers are short-circuit proof and feature thermal overload protection. The single phase transformers are provided with mounting holes for easy installation, and have two independent secondary windings, which may be connected in series or parallel. These highly efficient safety isolating ...