Telemecanique Sensors XCS-DMC Series Magnetic Non-Contact Safety Switch, 24V dc, Plastic Housing, NC, Cable
- RS Stock No.:
- 666-4975
- Mfr. Part No.:
- XCSDMC7902EX
- Brand:
- Telemecanique Sensors
Subtotal (1 unit)*
£119.69
(exc. VAT)
£143.63
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 23 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £119.69 |
*price indicative
- RS Stock No.:
- 666-4975
- Mfr. Part No.:
- XCSDMC7902EX
- Brand:
- Telemecanique Sensors
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Telemecanique Sensors | |
Supply Voltage | 24V dc | |
Safety Contacts | NC | |
Housing Material | Plastic | |
Connection Type | Cable | |
Actuator Type | Coded | |
Auxiliary Contacts | NO | |
Safety Category | 4 | |
Sensor Principle | Magnetic | |
Actuator Included | Yes | |
Range | Preventa | |
Switching Distance | 5 mm | |
Series | XCS-DMC | |
IP Rating | IP66, IP67 | |
Hazardous Area Certification | ATEX | |
Width | 34mm | |
Number of Approach Directions | 3 | |
Length | 51mm | |
Depth | 7mm | |
Select all | ||
---|---|---|
Brand Telemecanique Sensors | ||
Supply Voltage 24V dc | ||
Safety Contacts NC | ||
Housing Material Plastic | ||
Connection Type Cable | ||
Actuator Type Coded | ||
Auxiliary Contacts NO | ||
Safety Category 4 | ||
Sensor Principle Magnetic | ||
Actuator Included Yes | ||
Range Preventa | ||
Switching Distance 5 mm | ||
Series XCS-DMC | ||
IP Rating IP66, IP67 | ||
Hazardous Area Certification ATEX | ||
Width 34mm | ||
Number of Approach Directions 3 | ||
Length 51mm | ||
Depth 7mm | ||
XCS-DMC, Coded Hazardous Area
Ex coded magnetic safety switches can be used in potentially explosive DUSTY or GASEOUS environments for safety applications, for example on machines fitted with small guards or covers (with loose alignment), packaging machines, food and beverage processing (sugar refinery, malt house manufacturers, flour mills), petrochemical plants etc. They are approved for use in ATEX Zones 0-1-2 / 20-21-22, and can be used with XPS-DMB safety relays.
Protection modes mb, tD and ia
Suitable for Category 4/PLe circuits (EN ISO 13849-1)
Pre-cabled connection
Degree of protection: IP66 & IP67
Operating zone: Sao = 5 mm, Sar = 15 mm
Dimensions: 16 x 7 x 51mm
Suitable for Category 4/PLe circuits (EN ISO 13849-1)
Pre-cabled connection
Degree of protection: IP66 & IP67
Operating zone: Sao = 5 mm, Sar = 15 mm
Dimensions: 16 x 7 x 51mm
Group and Category
II 2 GD - Ex mb II T4
II 2 GD - Ex tD A21 IP67 T135 °C
II 1 GD - Ex ia IIB T4
II 1 GD - Ex iaD 20 T135 °C
II 2 GD - Ex tD A21 IP67 T135 °C
II 1 GD - Ex ia IIB T4
II 1 GD - Ex iaD 20 T135 °C