IDEM CMR Series Magnetic Non-Contact Safety Switch, 250V ac, 316 Stainless Steel Housing, 2NC, 5m Cable
- RS Stock No.:
- 123-7507
- Mfr. Part No.:
- 138022
- Brand:
- IDEM
Subtotal (1 unit)*
£133.55
(exc. VAT)
£160.26
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 25 unit(s) ready to ship
- Plus 8 unit(s) shipping from 21 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £133.55 |
*price indicative
- RS Stock No.:
- 123-7507
- Mfr. Part No.:
- 138022
- Brand:
- IDEM
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | IDEM | |
Supply Voltage | 250V ac | |
Safety Contacts | 2NC | |
Housing Material | 316 Stainless Steel | |
Connection Type | 5m Cable | |
Actuator Type | Magnetic | |
Auxiliary Contacts | NO | |
Safety Category | 4 | |
Sensor Principle | Magnetic | |
Actuator Included | Yes | |
Switching Distance | 10 (Close) mm, 22 (Open) mm | |
Series | CMR | |
Range | HYGIEMAG | |
IP Rating | IP67, IP69K | |
Supply Current | 1000mA | |
Standards Met | CE, cULus Listed, TUV Certified | |
Depth | 17mm | |
Number of Approach Directions | 2 | |
Width | 20.6mm | |
Length | 85mm | |
Select all | ||
---|---|---|
Brand IDEM | ||
Supply Voltage 250V ac | ||
Safety Contacts 2NC | ||
Housing Material 316 Stainless Steel | ||
Connection Type 5m Cable | ||
Actuator Type Magnetic | ||
Auxiliary Contacts NO | ||
Safety Category 4 | ||
Sensor Principle Magnetic | ||
Actuator Included Yes | ||
Switching Distance 10 (Close) mm, 22 (Open) mm | ||
Series CMR | ||
Range HYGIEMAG | ||
IP Rating IP67, IP69K | ||
Supply Current 1000mA | ||
Standards Met CE, cULus Listed, TUV Certified | ||
Depth 17mm | ||
Number of Approach Directions 2 | ||
Width 20.6mm | ||
Length 85mm | ||
- COO (Country of Origin):
- GB
IDEM HYGIEMAG CMR Non Contact Safety Switch
The HYGIEMAG CMR safety switch has been developed for non-contact guard door interlocking of hinged, sliding or removable guard doors. It is ideal for applications that require a wide tolerance to misalignment, a high switching capacity or high levels of hygiene. When used with dual channel safety relays, the CMR safety switch can be used to provide up to PLe/Category 4 to ISO13849-1 protection.
Features and Benefits
Magnetic high-power switching
Dual channel safety outputs
Stainless steel 316 housing
High temperature stability up to 105°C
Can be mounted on steel structures
High tolerance to guard misalignment
IP69K protection
Conformance to EN60947-5-3 PDF-S
Up to PLe ISO 13849-1
Slim fitting for all industry applications
Suitable for food contact zones - EHEDG Guidelines
Mirror Polished Finish to Ra4
Suitable for CIP and SIP cleaning
Easy to install within narrow frame structures
Operates from two sides for ease of applications
2NC / 1 NO
12 mm wide sensing
Switching capacity 1 A
55 & 73 mm fixing centres
Housing: 20.6 x 85 x 17 mm
Dual channel safety outputs
Stainless steel 316 housing
High temperature stability up to 105°C
Can be mounted on steel structures
High tolerance to guard misalignment
IP69K protection
Conformance to EN60947-5-3 PDF-S
Up to PLe ISO 13849-1
Slim fitting for all industry applications
Suitable for food contact zones - EHEDG Guidelines
Mirror Polished Finish to Ra4
Suitable for CIP and SIP cleaning
Easy to install within narrow frame structures
Operates from two sides for ease of applications
2NC / 1 NO
12 mm wide sensing
Switching capacity 1 A
55 & 73 mm fixing centres
Housing: 20.6 x 85 x 17 mm
Applications
The HYGIEMAG CMR non-contact safety switch is ideal for the food processing, pharmaceutical, packaging and chemical industries.
Note
The normally closed (NC) circuits are closed when the guard is closed and the actuator is present.
Standards
EN1088 (ISO 14119), EN 60947-5-1, EN 60204-1, ISO 13849-1, EN 62061, UL 508.
Approvals
CE, cULus, TUV.
Supplied with
Actuator.