Broyce Control Phase, Voltage Monitoring Relay With SPDT Contacts, 400 V ac Supply Voltage

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

LX Series - Three Phase Relays

L Series relay range of timers, control and three phase relays incorporate the latest technology and offer a wide range of user adjustable features.

17.5mm DIN rail housing
Microprocessor based
Measures phase to phase voltages
1 x SPDT relay output 8A
Green LED indication for supply status
Red LED indication for relay status

Approvals

UL Certification

Specifications
Attribute Value
Monitoring Application Phase, Voltage
Supply Voltage 400 V ac
Contact Configuration SPDT
Voltage Sensitivity Overvoltage, Undervoltage
Voltage Sensing Range 300 → 380 (Under) V, 420 → 500 (Over) V
Phase Sensitivity Phase Failure
Time Delay 0.2 → 10 s
Current Range Maximum of 8 A
Minimum Operating Temperature -20°C
Width 17.5mm
Maximum Operating Temperature +60°C
Mounting Type DIN Rail
Height 89mm
Operating Temperature Range -20 → +60 °C
Terminal Type Screw
Special Features Time Delay
Length 66.5mm
Series L-Series
Standards Met IEC 60664
Dimensions 17.5 x 89 x 66.5 mm
9 In stock for FREE next working day delivery
Price Each
£ 60.48
(exc. VAT)
£ 72.58
(inc. VAT)
Units
Per unit
1 - 4
£60.48
5 +
£58.03
Related Products
3 Phase Voltage Monitoring Relay with NO/NC Contact ...
Description:
3 Phase Voltage Monitoring Relay with NO/NC Contact Configuration. Features & Benefits Incorrect Phase Sequence Phase loss Phase undervoltage (0.6 x Un)Adjustable fault delay LED indication Write on ID tab Dimensions: H78 x W45 x D99mm.
Multi range Adjustable hysteresis Latching facility Adjustable fault ...
Description:
Multi range Adjustable hysteresis Latching facility Adjustable fault delay Adjustable start -up delay Switchable relay inversion LED indication Write on ID tab Dimensions: H78 x W45 x D99mm.
Separate relay & LED operation for three phase ...
Description:
Separate relay & LED operation for three phase monitoring 'V' & thermistor monitoring 'T'The relay monitors the following:Incorrect phase sequence/rotation Threshold voltage 60% of 400Vac Phase failure/loss Phase under-voltage (0.6 x 400Vac)Thermistor over-temperature Thermistor open circuit Thermistor short circuit Output relay: 10A (thermistor)Output relay: 10A (3 phase).
Detects under and over-voltage condition Adjustment for under ...
Description:
Detects under and over-voltage condition Adjustment for under and over trip levels Adjustable hysteresis Monitors own supply Separate relays for under and over Time delay: 200 ms (from fault)2 x DPDT relay output 8ALED indication for supply and relay statuses70 mm housing, DIN Rail or surface mount Dimensions: H70 x ...