Dold LH5946 Standstill Monitoring Relay With 3NO/NC Contacts, 230 V ac

  • RS Stock No. 181-2785
  • Mfr. Part No. LH5946.48/61 0,2-4V UH=AC230V 0,2-6s
  • Brand Dold
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Safe standstill detection on 3and single-phase motorsNo external sensors necessaryIndependent of directionBroken wire detectionForcibly guided safety contacts:3 NO contacts, 1 NC contact for AC 250 V2 semiconductor monitoring outputs1 monitoring output (NO contact)Adjustable voltage settingAdjustable standstill time delayLED indicators for standstill, event of line breakage and operation voltageSuitable for operation with invertersWidth 45 mmAdvantages / Customer benefitWithout sensor and safeFast reaction timeEasy to retrofitCombined with Interlock SAFEMASTER STS

Specifications
Attribute Value
Monitoring Application Standstill
Supply Voltage 230 V ac
Contact Configuration 3NO/NC
Voltage Sensing Range 0.2 4 V
Time Delay 0.2 6 s
Terminal Type Screw
Mounting Type DIN Rail
Maximum Voltage Sensed 4V
Height 90mm
Dimensions 45 x 121 x 90 mm
Maximum Operating Temperature +60°C
Operating Temperature Range -25 +60 °C
Minimum Operating Temperature -25°C
Minimum Voltage Sensed 0.2 V
Series LH5946
Length 45mm
Width 121mm
1 In stock for delivery within 1 working days
Price Each
£ 429.92
(exc. VAT)
£ 515.90
(inc. VAT)
Units
Per unit
1 +
£429.92
Not available for guaranteed pre 9am/10am delivery
Related Products
Senses pulses from a proximity detector mounted near ...
Description:
Senses pulses from a proximity detector mounted near a machine shaft rotating at up to 10000rpm LED indication of relay status and supply DIN standard case, which may be front panel or chassis mounted (11-pin socket 403-869)Additional fail safe with time delay adjustment between 1-30 seconds45mm x 45mm panel cut-out ...
DIN standard case, which may be front panel ...
Description:
DIN standard case, which may be front panel or chassis mounted (11-pin socket 403-869). Monitors the speed of machinery via the inputs from RS inductive proximity switches, open collector transistor or relay contact type devices On-board 24V dc supply for proximity device and an output suitable to drive a 100μA ...
Standstill recognition for 3-phase and single-phase asynchronous motors, ...
Description:
Standstill recognition for 3-phase and single-phase asynchronous motors, e.g. for safety door lock releases on machine tools or for activating parking brakes.The BD5936.17 measures the induced voltage of the slowing motor at two terminals on the stator winding. No initiator etc. is necessary. Frequency converter-driven motors cannot be monitored with ...
Monitoring of 3 phase systems for undervoltage or ...
Description:
Monitoring of 3 phase systems for undervoltage or phase failure and activation of security lighting in accordance with VDE 0108 (IEC 255, VDE 0435 Part 303). Single phase connection also an option Fixed fall-back value Closed circuit current principle LED display of switch state Adjustable phase sequence2 changeovers35 mm overall ...