Dold Insulation Monitoring Relay With 2 x 1CO Contacts, 24 V dc Supply Voltage

  • RS Stock No. 181-2776
  • Mfr. Part No. MK5880N.38/200 DC24V 5-100kOhm VW10k-5MOhm
  • Brand Dold
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
Monitors also disconnected voltage systems
Adjustable tripping value RALof 5 ... 100 kΩ
De-energized on trip
Auxiliary voltage, measuring circuit and output contacts are galvanically separated
Manual and auto reset
With test and reset button
Connections for external test and reset buttons possible
LED indicators for operation and alarm
2 changeover contacts
MK 5880N/200 with additional pre warning
adjustable pre warning value 10 kΩ ... 5 MΩ
1 output relay for alarm and 1 for pre-warning
MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals

Specifications
Attribute Value
Monitoring Application Insulation
Supply Voltage 24 V dc
Contact Configuration 2 x 1CO
Voltage Sensing Range 0 → 500 V ac
Dimensions 22.5 x 97 x 90 mm
Maximum Operating Temperature +60°C
Series MK5880N
Terminal Type Screw
Operating Temperature Range -20 → +60 °C
Minimum Voltage Sensed 0 V ac
Width 97mm
Length 22.5mm
Minimum Operating Temperature -20°C
Height 90mm
Maximum Voltage Sensed 500V ac
Mounting Type DIN Rail
1 In stock for delivery within 1 working days
Price Each
£ 170.45
(exc. VAT)
£ 204.54
(inc. VAT)
Units
Per unit
1 +
£170.45
Not available for guaranteed pre 9am/10am delivery
Related Products
DIN standard case, which may be front panel ...
Description:
DIN standard case, which may be front panel or chassis mounted (11-pin socket 403-869). Monitors the speed of machinery via the inputs from RS inductive proximity switches, open collector transistor or relay contact type devices On-board 24V dc supply for proximity device and an output suitable to drive a 100μA ...
Created and designed to provide you with reliable ...
Description:
Created and designed to provide you with reliable information on how your system is performing. Using the relays enables you to monitor and detect power loss from damaged or contaminated panels quickly meaning that you can respond immediately. These RM35 JA current control relays are also used for controlling alternating ...
For AC and DC systems Type BTo detect ...
Description:
For AC and DC systems Type BTo detect earth faults in grounded voltage systems4 setting ranges from 10 mA to 3 AManual reset, with alarm and pre-warning With adjustable switching delay Energized or de-energized on trip LED indicator for operation, pre-alarm and alarm With test function LED-chain indicates fault current ...
3UG4 relays that monitor current, power factor and ...
Description:
3UG4 relays that monitor current, power factor and active current are ideal for monitoring the load of motors and functionality of electronic loads. These devices detect the effect of wear and faults early on. This means that appropriate actions can be taken before more significant damage occurs. Wide voltage range ...