Schneider Electric Acti9 Acti9 iC60 MCB, 1P, 25A Curve B, 500V AC, 72V DC, 240 V Breaking Capacity
- RS Stock No.:
- 458-794
- Mfr. Part No.:
- A9F93125
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£69.60
(exc. VAT)
£83.52
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £69.60 |
*price indicative
- RS Stock No.:
- 458-794
- Mfr. Part No.:
- A9F93125
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Number of Poles | 1 | |
Current Rating | 25A | |
Tripping Characteristics | Type B | |
Rated AC Voltage | 500V | |
Rated DC Voltage | 72V | |
Breaking Capacity at Maximum Voltage Rating | 240 V | |
Range | Acti9 | |
Series | Acti9 iC60 | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Number of Poles 1 | ||
Current Rating 25A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 500V | ||
Rated DC Voltage 72V | ||
Breaking Capacity at Maximum Voltage Rating 240 V | ||
Range Acti9 | ||
Series Acti9 iC60 | ||
- COO (Country of Origin):
- FR
The Schneider Electric Low voltage miniature circuit breaker (MCB). It has 1P with 1 protected pole, rated current 25A and B tripping curve. The rated short circuit breaking capacity goes up to 25kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 15000A at 230VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker is for protection against short circuit and overload current in all applications. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
Combine short-circuit and overload currents protection
Visitrip system for fast detection of faulty outgoers for shorter repair times
VisiSafe system for offering enhanced security when it comes to circuit protection
Option to add auxiliaries and remote monitoring and residual current device
Visitrip system for fast detection of faulty outgoers for shorter repair times
VisiSafe system for offering enhanced security when it comes to circuit protection
Option to add auxiliaries and remote monitoring and residual current device