SICK LFP0450 Series TDR Level Sensor Level Sensor, PNP Output, Stainless Steel 303 Body
- RS Stock No.:
- 285-2052
- Mfr. Part No.:
- LFP0450-G1NMB
- Brand:
- SICK
Subtotal (1 unit)*
£909.11
(exc. VAT)
£1,090.93
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 29 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £909.11 |
*price indicative
- RS Stock No.:
- 285-2052
- Mfr. Part No.:
- LFP0450-G1NMB
- Brand:
- SICK
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | SICK | |
Device Type | TDR Level Sensor | |
Switch Output | PNP | |
Body Material | Stainless Steel 303 | |
Cable Length | 450mm | |
Communication Protocol | IO-LINK | |
Minimum Operating Temperature | -20°C | |
Maximum Operating Temperature | +150°C | |
Maximum DC Voltage | 30V | |
Thread Size | G3/4 | |
Maximum Current | 100 mA | |
Process Connection | G3/4 | |
Maximum Pressure | 16bar | |
Series | LFP0450 | |
Standards Met | CE, cULus | |
Interface | IO-Link | |
Select all | ||
---|---|---|
Brand SICK | ||
Device Type TDR Level Sensor | ||
Switch Output PNP | ||
Body Material Stainless Steel 303 | ||
Cable Length 450mm | ||
Communication Protocol IO-LINK | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +150°C | ||
Maximum DC Voltage 30V | ||
Thread Size G3/4 | ||
Maximum Current 100 mA | ||
Process Connection G3/4 | ||
Maximum Pressure 16bar | ||
Series LFP0450 | ||
Standards Met CE, cULus | ||
Interface IO-Link | ||
- COO (Country of Origin):
- DE
Overview
The LFP Inox is a hygienic level sensor for liquids using TDR technology – a process for determining the time of flight of electromagnetic waves. The time difference between the sent pulse and the reflected pulse is used to generate a level signal, both as a continuous value (analogue output) and a freely positionable switching point (switching output). The use of FDA-compliant materials in an EHEDG-certified design means that the LFP Inox can be relied upon for optimum and unrestricted cleaning, even in applications with the most stringent hygiene requirements. Its modular connection system allows simple and flexible installation in any application.
Thanks to high temperature and pressure resistance, unrestricted use is possible under CIP and SIP conditions. This impressive profile is topped off with communication capability via IO-Link to the superordinate control units.
At a glance
Level measurement in hygienic applications
Rod probe can be cut to length manually up to 4,000 mm long with Ra ≤ 0.8 μm (optionally with Ra ≤ 0.4 μm)
Process temperature up to 180 °C, process pressure up to 16 bar
CIP/SIP-resistant
High enclosure rating: IP 67 and IP 69, autoclavable
Interchangeable hygienic process connections
3 in 1: combines display, analogue output, and binary output
Remote amplifier with process connection
IO-Link 1.1
Rod probe can be cut to length manually up to 4,000 mm long with Ra ≤ 0.8 μm (optionally with Ra ≤ 0.4 μm)
Process temperature up to 180 °C, process pressure up to 16 bar
CIP/SIP-resistant
High enclosure rating: IP 67 and IP 69, autoclavable
Interchangeable hygienic process connections
3 in 1: combines display, analogue output, and binary output
Remote amplifier with process connection
IO-Link 1.1
Your Benefit
Rugged design increases service life
High flexibility – rod probe can be cut to length and connection concept is interchangeable
Cost savings as a result of multiple output signals: one system for both point level and continuous level measurement
Maintenance-free and easy to commission without calibration, saving time and money
Remote display of measured values and saves space
High flexibility – rod probe can be cut to length and connection concept is interchangeable
Cost savings as a result of multiple output signals: one system for both point level and continuous level measurement
Maintenance-free and easy to commission without calibration, saving time and money
Remote display of measured values and saves space
Applications
Fields of applications
Level monitoring in buffer tanks of filling systems and filling machines
Level monitoring in rinsing systems
Level monitoring in CIP systems
Level measurement in mixing systems in the cosmetics and pharmaceuticals industry
Level mon
Level monitoring in buffer tanks of filling systems and filling machines
Level monitoring in rinsing systems
Level monitoring in CIP systems
Level measurement in mixing systems in the cosmetics and pharmaceuticals industry
Level mon
Related links
- SICK LFP Series TDR Level Sensor Level Sensor PNP Output Steel 303 Body
- SICK LFP0600 Series TDR Level Sensor Level Sensor PNP Output, 303 Steel Body
- SICK LFP0500 Series TDR Level Sensor Level Sensor Plastic PBT Body
- SICK LFP0800 Series TDR Level Sensor Level Sensor Plastic PBT Body
- SICK LFP0200 Series TDR Level Sensor Level Sensor PNP Output, Plastic PBT Body
- SICK LFP0600 Series TDR Level Sensor Level Sensor PNP Output, Plastic PBT Body
- SICK LFP0400 Series TDR Level Sensor Level Sensor PNP Output, Plastic PBT Body
- SICK LFP0900 Series TDR Level Sensor Level Sensor Plastic PBT Body