Peak Electronic Design ESR70 Handheld LCR Meter 22mF, 4 MΩ

Subtotal (1 unit)*

£99.08

(exc. VAT)

£118.90

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 54 unit(s) ready to ship
  • Plus 12 unit(s) ready to ship from another location
  • Plus 32 unit(s) shipping from 10 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£99.08

*price indicative

RS Stock No.:
685-8791
Mfr. Part No.:
ESR70
Brand:
Peak Electronic Design
Find similar products by selecting one or more attributes.
Select all

Brand

Peak Electronic Design

Maximum Capacitance Measurement

22mF

Maximum Resistance Measurement

4 MΩ

Battery Type

A23

Bench/Handheld

Handheld

Display Type

LCD

Power Source

Battery

Dimensions

103 x 70 x 20mm

Height

20mm

Length

103mm

Maximum Operating Temperature

+40°C

Minimum Operating Temperature

+10°C

Model Number p

ESR70

Width

70mm

COO (Country of Origin):
GB

Peak Electronic Design ESR70 Resistance and Capacitance LCR Meter


Measuring a capacitor's ESR (equivalent series resistance) is a good indicator of capacitor condition. You can use the Atlas ESR in-circuit, saving you the trouble of removing capacitors. When testing capacitors out-of-circuit, the unit will also display the capacitance. The ESR70 provides instant results when the test button is pressed, a range of tones are produced in feedback of the measurement results. Also included extra-long and extra-flexible test cables (450mm of Silicone covered cable), 2mm plugs and sockets with removeable gold plated crocodile clips, comprehensive illustrated user guide and GP23 Alkaline battery.

Features and Benefits:


• Resolution down to 0.01 ohms
• Analyses at industry standard of 100kHz
• Capable of In-Circuit testing
• Polarity free, connect any way round
• ESR range 0.00 to 40 Ohms
• Protected against highly-charged capacitors
• Gold plated crocodile probes with 4-wire Kelvin connections
• ESR70 has a special audio feature to aid quick measurement
• Automatic analysis-start when you apply the probes.
• Automatic capacitor discharge using controlled discharge function.
• ESR (and low DC resistance) measurement (even in-circuit).
• Optional probe alternatives easily fitted.

Related links