Keysight Technologies LCR Meter Accessory for Use with E4980A/AL, E4981A, E4990A, E5061B-3L3/3L4/3L5 with Opt. 005
- RS Stock No.:
- 245-5591
- Mfr. Part No.:
- 16034H
- Brand:
- Keysight Technologies
Subtotal (1 unit)*
£2,649.23
(exc. VAT)
£3,179.08
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 01 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £2,649.23 |
*price indicative
- RS Stock No.:
- 245-5591
- Mfr. Part No.:
- 16034H
- Brand:
- Keysight Technologies
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Keysight Technologies | |
Accessory Type | SMD | |
For Use With | E4980A/AL, E4981A, E4990A, E5061B-3L3/3L4/3L5 with Opt. 005 | |
Select all | ||
---|---|---|
Brand Keysight Technologies | ||
Accessory Type SMD | ||
For Use With E4980A/AL, E4981A, E4990A, E5061B-3L3/3L4/3L5 with Opt. 005 | ||
- COO (Country of Origin):
- MY
The Keysight Technologies 16034H this test fixture is designed for impedance evaluations of array-type SMD. The minimum SMD size that this fixture is adapted to evaluate is 1.6(L) x 0.8(W) [mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact the each element of the array-type component.
Open and short compensations are recommended before measurement
When measuring above 3 MHz, load compensation is also recommended
Open compensation is performed by separating the high and the low electrodes from each other
The separation should be equivalent in size to the DUTs width
Short compensation is performed by placing the high and low electrodes in contact together
Load compensation is performed by using the furnished 100 Ω SMD chip resistor
After performing open, short and load compensations, the DUT is inserted into the test fixture
When measuring above 3 MHz, load compensation is also recommended
Open compensation is performed by separating the high and the low electrodes from each other
The separation should be equivalent in size to the DUTs width
Short compensation is performed by placing the high and low electrodes in contact together
Load compensation is performed by using the furnished 100 Ω SMD chip resistor
After performing open, short and load compensations, the DUT is inserted into the test fixture
Note
Manufacturers Warranty
Related links
- Keysight Technologies LCR Meter Accessory for Use with E4980A/AL E4990A, E5061B-3L3/3L4/3L5 with Opt. 005
- Keysight Technologies LCR Meter Accessory for Use with E4980A/AL E4990A, E5061B-3L3/3L4/3L5
- Keysight Technologies LCR Meter Accessory for Use with E4980A/AL E4990A
- Keysight Technologies LCR Meter Accessory for Use with E4980A/AL, E4981A
- Keysight Technologies LCR Meter Accessory for Use with E4980A/AL
- Keysight Technologies LCR Meter Adapter for Use with LCR Meter
- Keysight Technologies LCR Meter Accessory
- Keysight Technologies LCR Meter Accessory for Use with E5270