Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | SICK | |
Media Monitored | Liquid | |
Device Type | Fluid Sensor | |
Minimum Flow Rate | 3 cm/s | |
Maximum Flow Rate | 600 cm/s | |
Supply Voltage | 9 → 30 V dc | |
Pipe Diameter Range | 25 mm | |
Connection Type | M12 Connector | |
Maximum Pressure | 100bar | |
Material | VISTAL | |
Minimum Media Temperature | -40 | |
Minimum Operating Temperature | -40°C | |
Maximum Operating Temperature | +70°C | |
Series | FTS | |
Current Rating | 100 mA | |
Select all | ||
---|---|---|
Brand SICK | ||
Media Monitored Liquid | ||
Device Type Fluid Sensor | ||
Minimum Flow Rate 3 cm/s | ||
Maximum Flow Rate 600 cm/s | ||
Supply Voltage 9 → 30 V dc | ||
Pipe Diameter Range 25 mm | ||
Connection Type M12 Connector | ||
Maximum Pressure 100bar | ||
Material VISTAL | ||
Minimum Media Temperature -40 | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature +70°C | ||
Series FTS | ||
Current Rating 100 mA | ||
- COO (Country of Origin):
- DE
Overview
The T-Easic FTS thermal flow sensor measures flow and temperature of liquids in accordance with the calorimetric principle. Available as an industrial variant with VISTAL® housing and display or as a hygienic stainless-steel variant, the T-Easic® FTS is s
A special feature is integrated empty pipe detection for optimal dry-run protection in pumps. Parameterization can be done via IO-Link or the display. Media taught-in at the factory such as oil and water accelerate commissioning
other liquids can be cali
At a glance
Flow monitoring and temperature measurement in one sensor
Optimized for water and oil
Optimized for water and oil
teach-in option of other liquids
IP 67/IP 69 enclosure rating and IO-Link 1.1
Industrial design in VISTAL® housing with 180°-rotatable OLED display
Stainless steel hygi
IP 67/IP 69 enclosure rating and IO-Link 1.1
Industrial design in VISTAL® housing with 180°-rotatable OLED display
Stainless steel hygi
Your Benefit
One sensor, two measurements – reduces costs and hygiene risk thanks to a unique installation point
Optimal pump protection thanks integrated empty pipe detection
Automated measurement data acquisition via analogue output or IO-Link
Volume recording thank
Optimal pump protection thanks integrated empty pipe detection
Automated measurement data acquisition via analogue output or IO-Link
Volume recording thank
Applications
Note
Product details cover the whole product family. For details on the specifications for this individual product, please refer to the datasheet.