Honsberg Compact Mount Flow Controller, 1 → 150 (Water) cm³/s, 3 → 300 (Oil) cm³/s, Analogue Output, 18
- RS Stock No.:
- 619-4460
- Brand:
- Honsberg
Image representative of range
Unavailable
RS will no longer stock this product.
- RS Stock No.:
- 619-4460
- Brand:
- Honsberg
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honsberg | |
| Maximum Flow Rate | 1 → 150 (Water) cm³/s, 3 → 300 (Oil) cm³/s | |
| Electrical Connection | M12 Connector | |
| Control Output | Analogue | |
| Mounting Style | Compact | |
| Supply Voltage | 18 → 30 V dc | |
| Display Screen | LCD | |
| Pipe Diameter Range | 1/2 in | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | +70°C | |
| Select all | ||
|---|---|---|
Brand Honsberg | ||
Maximum Flow Rate 1 → 150 (Water) cm³/s, 3 → 300 (Oil) cm³/s | ||
Electrical Connection M12 Connector | ||
Control Output Analogue | ||
Mounting Style Compact | ||
Supply Voltage 18 → 30 V dc | ||
Display Screen LCD | ||
Pipe Diameter Range 1/2 in | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +70°C | ||
- COO (Country of Origin):
- DE
Provides maximum and minimum flow rate data for use with flow/no-flow sensing applications
Flow setting ranges: 20 to 50cm/s
Programmed using the rotating programming ring
Continual display (LCD; LED red) of flow rate as a percentage of maximum
Power consumption: <1W
Protection to IP67
2s response time (approx.) dependent on flow rate
1% repeat accuracy
Switching outputs: PNP, NPN - 300mA maximum
Five-pole, M12 plug connector
Supply voltage: 18 to 30Vdc
Analogue output: 4 to 20mA
Minimum or maximum switching points with adjustable hysteresis
User-defined flow rate range
Programming ring is removable for security
Flow setting ranges: 20 to 50cm/s
Programmed using the rotating programming ring
Continual display (LCD; LED red) of flow rate as a percentage of maximum
Power consumption: <1W
Protection to IP67
2s response time (approx.) dependent on flow rate
1% repeat accuracy
Switching outputs: PNP, NPN - 300mA maximum
Five-pole, M12 plug connector
Supply voltage: 18 to 30Vdc
Analogue output: 4 to 20mA
Minimum or maximum switching points with adjustable hysteresis
User-defined flow rate range
Programming ring is removable for security