Digitron 2006T Wired Digital Thermometer for Multipurpose Use, Type T Thermocouple Probe, 1 Input(s), +400°C Max, ±0.2
- RS Stock No.:
- 315-5232
- Mfr. Part No.:
- 2006T
- Brand:
- Digitron
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS Stock No.:
- 315-5232
- Mfr. Part No.:
- 2006T
- Brand:
- Digitron
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Digitron | |
Absolute Maximum Temperature Measurement | +400°C | |
Calibrated | RSCAL | |
Model Number | 2006T | |
Thermometer Type | Wired | |
Probe Type | T | |
Application | Multipurpose | |
Best Accuracy | ±0.2 °C | |
Number of Temperature Inputs | 1 | |
Resolution | 0.1 °C | |
Data Storage | Yes | |
Length | 155mm | |
Width | 67mm | |
Height | 40mm | |
Temperature Scale | Centigrade, Fahrenheit | |
Battery Type | AA | |
Weight | 180g | |
Select all | ||
---|---|---|
Brand Digitron | ||
Absolute Maximum Temperature Measurement +400°C | ||
Calibrated RSCAL | ||
Model Number 2006T | ||
Thermometer Type Wired | ||
Probe Type T | ||
Application Multipurpose | ||
Best Accuracy ±0.2 °C | ||
Number of Temperature Inputs 1 | ||
Resolution 0.1 °C | ||
Data Storage Yes | ||
Length 155mm | ||
Width 67mm | ||
Height 40mm | ||
Temperature Scale Centigrade, Fahrenheit | ||
Battery Type AA | ||
Weight 180g | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Digitron 2006T Digital Thermometer
Digitron's 2006T Type T thermocouple based thermometer has been designed specifically for the food industry. Meeting the UK and International food hygiene guidelines.
Backlight
Display hold
Optional auto power off after 12 minutes
Low battery indication
Set up retention (when switched on the last settings used are displayed)
For T type thermocouples
Probes required for use with the 2006T are standard 2 pin type T thermocouples
This instrument can be calibrated with the probes listed as a system calibration. To order this calibration please use the System Cal. stock no. of the probe and the System Cal stock no. of the instrument.
Display hold
Optional auto power off after 12 minutes
Low battery indication
Set up retention (when switched on the last settings used are displayed)
For T type thermocouples
Probes required for use with the 2006T are standard 2 pin type T thermocouples
This instrument can be calibrated with the probes listed as a system calibration. To order this calibration please use the System Cal. stock no. of the probe and the System Cal stock no. of the instrument.