LEM LTS Series Closed Loop Current Sensor, 0 → ±80A nominal current

  • RS Stock No. 301-9473
  • Mfr. Part No. LTS 25NP
  • Brand LEM
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

LTS - P Series

Single-pole closed-loop current transducers based on the Hall effect principle
Voltage output
3 different input ranges via selection pins
Compact format for mounting on p.c.b.
Excellent precision and good linearity
Low temperature drift
Body material plastic to UL94-V0

Specifications
Attribute Value
Sensor Technology Closed Loop
Nominal Current 0 → ±80A
Supply Voltage 5 V
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth DC 100 to 200 kHz
Accuracy ±0.2 %
Bore Size 3.2mm
Series LTS
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Depth 10mm
Height 24mm
Width 22.2mm
123 In stock for FREE next working day delivery
Price Each
£ 13.31
(exc. VAT)
£ 15.97
(inc. VAT)
Units
Per unit
1 - 4
£13.31
5 - 9
£12.91
10 +
£12.35
Related Products
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage ...
Description:
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage output, Vout = ±4VCapable of measuring complex signalsExcellent precision and good linearityLow temperature driftBody material Plastic; Polycarbonate PBTOperating Temperature Range -10 to +80°CSecondary connector: stock no. 543-7738.
Compact PCB mounting designEta technologyExternal reference input (Stock ...
Description:
Compact PCB mounting designEta technologyExternal reference input (Stock No. 435-8779)Very low temperature driftWide frequency responseHigh noise immunityCurrent overload capacityBody material plastic to UL94-V0.
Current transducers LF-S Series for the electronic measurement ...
Description:
Current transducers LF-S Series for the electronic measurement of currents: dc, ac, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. They are speciallly designed for industrial applications. Measurement of ac, dc and pulsed currentsHigh Accuracy - Closed LoopHigh Noise ImmunityLow Temperature DriftCurrent Overload CapabilityOptimised response timeWide ...
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.