Chauvin Arnoux K1 Clamp Meter, 4.5A dc, Max Current 3A ac CAT II 300 V
- RS Stock No.:
- 216-6679
- Mfr. Part No.:
- P01120067A
- Brand:
- Chauvin Arnoux
- RS Stock No.:
- 216-6679
- Mfr. Part No.:
- P01120067A
- Brand:
- Chauvin Arnoux
Select all | Attribute | Value |
|---|---|---|
| Brand | Chauvin Arnoux | |
| Absolute Maximum AC Current Measurement | 3A ac | |
| Absolute Maximum DC Current Measurement | 4.5A dc | |
| Model Number | K1 | |
| AC Current Measurement Resolution | 100µA ac | |
| DC Current Measurement Resolution | 50µA dc | |
| Best DC Current Accuracy | ±1 % | |
| Clamp Meter Type | AC-DC Current Probe | |
| Best AC Current Accuracy | ±1 % | |
| Jaw Capacity Busbars | 3.9mm | |
| Functions Measured | AC Current, DC Current | |
| Dimensions | 124 x 64 x 28mm | |
| Length | 124mm | |
| Power Source | Battery | |
| Width | 64mm | |
| Safety Category Level | CAT II | |
| Weight | 250g | |
| Battery Life | 20 h | |
| Maximum Conductor Size | 3.9mm | |
| Maximum Operating Temperature | +55°C | |
| Safety Category | CAT II 300 V | |
| Battery Type | 9V | |
| Safety Category Voltage | 300V | |
| Minimum Operating Temperature | -10°C | |
| Height | 28mm | |
| Select all | ||
|---|---|---|
Brand Chauvin Arnoux | ||
Absolute Maximum AC Current Measurement 3A ac | ||
Absolute Maximum DC Current Measurement 4.5A dc | ||
Model Number K1 | ||
AC Current Measurement Resolution 100µA ac | ||
DC Current Measurement Resolution 50µA dc | ||
Best DC Current Accuracy ±1 % | ||
Clamp Meter Type AC-DC Current Probe | ||
Best AC Current Accuracy ±1 % | ||
Jaw Capacity Busbars 3.9mm | ||
Functions Measured AC Current, DC Current | ||
Dimensions 124 x 64 x 28mm | ||
Length 124mm | ||
Power Source Battery | ||
Width 64mm | ||
Safety Category Level CAT II | ||
Weight 250g | ||
Battery Life 20 h | ||
Maximum Conductor Size 3.9mm | ||
Maximum Operating Temperature +55°C | ||
Safety Category CAT II 300 V | ||
Battery Type 9V | ||
Safety Category Voltage 300V | ||
Minimum Operating Temperature -10°C | ||
Height 28mm | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- FR
K1 and K2 low-current probes
Easily adapted to all 19 mm standard spacing multimeters.
Zero reset using a thumb wheel with disable feature.
2 LEDs display overload (red LED) and the correct battery level (green LED).
Applications: loop measurements 4 → 20 mA without opening the circuit, low current measurements, default current measurements etc.
Standard: IEC 1010-1, 600 V Cat. III, deg. 2 if used with a multimeter of the same category.