Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Note

Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928

Approvals

8888

Standards

BS3535; EN 60 742

Open Laminated Clamp & Frame 115-230Vac Primary 6VA to 100VA

Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Specifications
Attribute Value
Primary Voltage Rating 115V ac, 230V ac
Secondary Voltage Rating 12V ac
Power Rating 6VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 45mm
Width 40mm
Depth 37mm
Dimensions 45 x 40 x 37mm
Fixing Hole Diameter 4 x 5.5mm
Weight 200g
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
52 In stock for FREE next working day delivery
Price Each
£ 7.99
(exc. VAT)
£ 9.59
(inc. VAT)
Units
Per unit
1 - 9
£7.99
10 - 24
£7.19
25 +
£6.74
Related Products
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Two hole fixing wrap-over ...
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.