Specifications
| Accuracy | 0.2 % | |
| Analogue Output | 25 → 45 mV | |
| Maximum Operating Temperature | +85°C | |
| Maximum Pressure Reading | 0.5psi | |
| Media Measured | Nitrogen Gas, Oxygen, Water | |
| Minimum Operating Temperature | -40°C | |
| Minimum Pressure Reading | 0psi | |
| Output Type | Unamplified | |
| Pressure Reading Type | Gauge | |
| Response Time | 1 ms | |
| Supply Voltage | 10 V dc | |
| Terminal Type | Solder Tag |
Not quite what you were looking for?
Quickly find other suitable products by removing those features above which are not essential and clicking Find.
Find
Quickly find other suitable products by removing those features above which are not essential and clicking Find.
Find
Non-compensated Gauge
For use with limited media, only those media which will not attack polyetherimide, silicone, fluorosilicone, EPDM and neoprene seals
Note
Temperature stability of output can be considerably increased by utilising constant current (2mA) energisation rather than constant voltage.
Supplied with
instruction leaflet
|