Radiodetection 10/ECAT4+EN61 Cable Avoidance Tool

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

eC.A.T4+ Cable Avoidance Tool

The eC.A.T4+ is a true digital cable avoidance tool, delivering highly refined location capabilities, specifically designed to help the operator find more buried utilities.

Operating modes:
Avoidance Mode: Simultaneously search for and pinpoint Genny, Power and Radio signals for rapid surveying
Genny mode: Detects the signals transmitted by Genny4, with on-demand metric estimation of the depth of buried utilities
Power mode: Detects the electromagnetic fields generated by loaded power cables
Radio mode: Detects long-range radio signals as they travel along buried cables and pipes
StrikeAlert Warning: Warns of shallow buried utilities
Swing Warning: Ground-breaking feature warns operators of incorrect usage to promote best working practices
High contrast display with auto-backlight: Bargraph ’tidemark’ enables operators to quickly spot and zero-in on a buried conductor
High speed USB 2.0 data connection: Connect to a PC to configure C.A.T settings, run an eCert, and to rapidly transfer usage data from eC.A.T4
Operating temperature range: -20°C to +50°C
Environmental protection: IP54
Batteries: 2 x LR20 (D) 1.5 V alkaline, Compatible with D type NiMH rechargeable batteries

Radiodetection eC. A. T4 Cable Avoidance Tool

The Radio detection eC. A. T4+ cable avoidance tool is a true digital cable avoidance tool, delivering highly refined location capabilities, specifically designed to help the operator find more buried utilities. It is mostly used for outdoor applications.
Cable avoidance tools:
Reliable cable avoidance systems to locate buried cables and metallic pipes and help prevent costly and potentially deadly cable hits. Twin differential antenna technology plus sophisticated signal processing techniques provide superior rejection of unwanted signals and accurately locates a response for effective operation in congested sites and sites with overhead cables.

Features and Benefits

• Avoidance mode: Simultaneously search for and pinpoint Genny, Power and Radio signals for rapid surveying
• Genny mode: Detects the signals transmitted by Genny4, with the on-demand metric estimation of the depth of buried utilities
• Power mode: Detects the electromagnetic fields generated by loaded power cables
• Radio mode: Detects long-range radio signals as they travel along buried cables and pipes
• Strike Alert Warning: Warns of shallow buried utilities
• Dynamic overload protection
• Depth estimation function
• High contrast display with auto-backlight: Bar graph ’tidemark’ enables operators to quickly spot and zero-in on a buried conductor
• High-speed USB 2.0 data connection: connect to a PC to configure C. A. T settings, run an eCert, and to rapidly transfer usage data from eC. A. T4
• Small diameter locate the frequency
• High contrast display with auto-backlight bar graph ’tidemark’ enables operators to quickly spot and zero-in on a buried conductor
• Operating temperature ranges from -20°C and 50°C
• 2 x LR20 (D) 1.5V alkaline, compatible with D type NiMH rechargeable batteries

Certifications

• IP54 rated

Cable Avoidance Tools

Reliable cable avoidance systems to locate buried cables and metallic pipes and help prevent costly and potentially deadly cable hits. Twin differential antenna technology plus sophisticated signal processing techniques provides superior rejection of unwanted signals and accurate locate response for effective operation in congested sites, and sites with overhead cables.

Specifications
Attribute Value
Cable Detection Depth 3 (Line) m, 7 (Sonde) m
Best Depth Accuracy ±5%
Best Location Accuracy ±10%
Depth Indicator Yes
Live AC Conductor Indicator Yes
Measurement Mode Power, Radio
Tester Type Cable Detection
Battery Type LR20 (D Type NiMH)
Power Source Battery
Weight 2.7kg
Maximum Operating Temperature +50°C
Minimum Operating Temperature -20°C
2 In stock for FREE next working day delivery
Price Each
£ 952.48
(exc. VAT)
£ 1,142.98
(inc. VAT)
Units
Per unit
1 +
£952.48
Related Products
A range of 1.57mm Diameter Standard .062" Pin ...
Description:
A range of 1.57mm Diameter Standard .062" Pin and Socket Crimp Terminal contacts available as gold-plated or tinned versions for use with receptacles housings stock number 236-2928 typically and for plug housings 236-2984 typically. • Shell Material: Nylon UL 94-V2• Colour: Neutral (natural nylon)• Current Rating: 5V• Voltage: 250V• 1 ...
A range of 1.57mm Diameter Standard .062" Pin ...
Description:
A range of 1.57mm Diameter Standard .062" Pin and Socket Crimp Terminal contacts available as gold-plated or tinned versions for use with receptacles housings stock number 236-2928 typically and for plug housings 236-2984 typically. • Shell Material: Nylon UL 94-V2• Colour: Neutral (natural nylon)• Current Rating: 5V• Voltage: 250V• 1 ...
Locate cable and wire ground faults, sheath faults ...
Description:
Locate cable and wire ground faults, sheath faults or pipeline coating defects, where the utility is in direct contact with the ground The intuitive transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 k Hz frequencies Ensures safety when working with energized cables ...
Suitable for QM single and two piece contacts. ...
Description:
Suitable for QM single and two piece contacts. Plier tool can also be used to crimp contacts for the Circular Sealed Industrial IP67 connector range and the Sealed Industrial IP68 connector range stock no. 489-526. Instructions supplied with tools. RF shielding inherent in the full metal construction Backshells enable cable ...