The eC.A.T4+ is a true digital cable avoidance tool, delivering highly refined location capabilities, specifically designed to help the operator find more buried utilities.
Operating modes:
Avoidance Mode: Simultaneously search for and pinpoint Genny, Power and Radio signals for rapid surveying
Genny mode: Detects the signals transmitted by Genny4, with on-demand metric estimation of the depth of buried utilities
Power mode: Detects the electromagnetic fields generated by loaded power cables
Radio mode: Detects long-range radio signals as they travel along buried cables and pipes
StrikeAlert Warning: Warns of shallow buried utilities
Swing Warning: Ground-breaking feature warns operators of incorrect usage to promote best working practices
High contrast display with auto-backlight: Bargraph tidemark enables operators to quickly spot and zero-in on a buried conductor
High speed USB 2.0 data connection: Connect to a PC to configure C.A.T settings, run an eCert, and to rapidly transfer usage data from eC.A.T4
Operating temperature range: -20°C to +50°C
Environmental protection: IP54
Batteries: 2 x LR20 (D) 1.5 V alkaline, Compatible with D type NiMH rechargeable batteries
The Radio detection eC. A. T4+ cable avoidance tool is a true digital cable avoidance tool, delivering highly refined location capabilities, specifically designed to help the operator find more buried utilities. It is mostly used for outdoor applications.
Cable avoidance tools:
Reliable cable avoidance systems to locate buried cables and metallic pipes and help prevent costly and potentially deadly cable hits. Twin differential antenna technology plus sophisticated signal processing techniques provide superior rejection of unwanted signals and accurately locates a response for effective operation in congested sites and sites with overhead cables.
Avoidance mode: Simultaneously search for and pinpoint Genny, Power and Radio signals for rapid surveying
Genny mode: Detects the signals transmitted by Genny4, with the on-demand metric estimation of the depth of buried utilities
Power mode: Detects the electromagnetic fields generated by loaded power cables
Radio mode: Detects long-range radio signals as they travel along buried cables and pipes
Strike Alert Warning: Warns of shallow buried utilities
Dynamic overload protection
Depth estimation function
High contrast display with auto-backlight: Bar graph tidemark enables operators to quickly spot and zero-in on a buried conductor
High-speed USB 2.0 data connection: connect to a PC to configure C. A. T settings, run an eCert, and to rapidly transfer usage data from eC. A. T4
Small diameter locate the frequency
High contrast display with auto-backlight bar graph tidemark enables operators to quickly spot and zero-in on a buried conductor
Operating temperature ranges from -20°C and 50°C
2 x LR20 (D) 1.5V alkaline, compatible with D type NiMH rechargeable batteries
IP54 rated
Reliable cable avoidance systems to locate buried cables and metallic pipes and help prevent costly and potentially deadly cable hits. Twin differential antenna technology plus sophisticated signal processing techniques provides superior rejection of unwanted signals and accurate locate response for effective operation in congested sites, and sites with overhead cables.
Attribute | Value |
---|---|
Cable Detection Depth | 3 (Line) m, 7 (Sonde) m |
Best Depth Accuracy | ±5% |
Best Location Accuracy | ±10% |
Depth Indicator | Yes |
Live AC Conductor Indicator | Yes |
Measurement Mode | Power, Radio |
Tester Type | Cable Detection |
Battery Type | LR20 (D Type NiMH) |
Power Source | Battery |
Weight | 2.7kg |
Maximum Operating Temperature | +50°C |
Minimum Operating Temperature | -20°C |