United Automation, PAC-2, Thyristor Trigger Module, 250V ac, 57 x 44 x 28mm

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

25A Phase Angle Power Controller, PAC2

A single phase, compact ac phase angle power controller capable of regulating loads up to 6kW.

Controls the amount of power to the load via a remote 0-5V proportional signal or by using a manual potentiometer
Suitable for infrared quartz and ceramic heaters and lighting applications

Supply voltage 230V ac ±10% 50/60Hz
Limiting current 25A rms
Power consumption 1.2W
Leakage current 5mA
Line supply 10V ac @ 50mA
Control signal 0-5V/5V O/P
Operating temperature +65°C (max)
//media.rs-online.com/t_line/L0379651-10.gif
//media.rs-online.com/t_line/L379651-01.gif
Specifications
Attribute Value
Input Voltage AC 250V ac
Output Isolation 3500Vrms
Mounting Type Screw Mount
Dimensions 57 x 44 x 28mm
Length 57mm
Height 28mm
Width 44mm
Maximum Operating Temperature +65 °C
28 In stock for FREE next working day delivery
Price Each
£ 59.76
(exc. VAT)
£ 71.71
(inc. VAT)
Units
Per unit
1 - 1
£59.76
2 - 4
£54.98
5 - 9
£50.59
10 - 19
£44.57
20 +
£43.69
Related Products
Splitters for XE plug-in technology.A connector combined with ...
Description:
Splitters for XE plug-in technology.A connector combined with a splitter supplies two rows. stock no. 145-279.Rated operating current: 63 A @ 40 °C.Rated insulating voltage: 250 VacMounting on support provided at the back of the symmetrical rail on Opale and Pragma evolution enclosures.
The number of complete mains cycles during fixed ...
Description:
The number of complete mains cycles during fixed repeating periods (typically 1 to 10 seconds) is varied, thus altering the duty cycle or on-/off-time ratio. Trigger pulses coincide with the zero-crossing times of the mains supply thus ensuring no RFI is produced when using resistive loads. "Human Machine Interface" (HMI), ...
3-Channel AC/DC Variable Fan Failure Alarm in a ...
Description:
3-Channel AC/DC Variable Fan Failure Alarm in a DIN Mountable EnclosureDetects open and short circuit failuresStandard Din Rail mount EnclosureAdjustable set pointAC or DC FansPower indication LEDThree (3) fan failure indication LEDVariable alarm delay 1 to 60 secondsThree (3) Volt free Relay outputs (one per fan)Works with fans up to ...
The TRAP-Sx system is a very robust and ...
Description:
The TRAP-Sx system is a very robust and easy to use remote control system. The receiver has four independent outputs that can be paired with individual switches from one or many different transmitters. No of Rx channels: 4No of Tx buttons: up to 16Carrier frequency: 869.5MHz ISM BandRF Power Output: ...