EPCOS Switching Spark Gap, 5000V Breakdown Voltage, 30A, 100Hz Max. Switching Frequency

  • RS Stock No. 167-0454
  • Mfr. Part No. B88069X0270S102
  • Brand EPCOS
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Miniature Gas Filled, B88069X Axial series

High Energy, low loss capable
Wide operating temperature range
Long service life due to robust design
Stable performance over life

Switching Spark Gaps (GDT)

Switching spark gaps are designed specifically for voltage controlled switching of capacitive discharge circuits where a high energy, low loss, fast rate of switching is required. These products are ideally suited for applications where a capacitive discharge is utilised with a transformer to obtain pulses of high-voltage levels in the order of several thousand volts. Utilised in gas heating and gas appliances along with protection of Xenon discharge lamps in both the architectural and automotive areas.

Specifications
Attribute Value
Breakdown Voltage 5000V
Peak Current 30A
Maximum Switching Frequency 100Hz
Overall Length 60mm
Lead Length 60mm
Tube Diameter 0.8mm
Minimum Operating Temperature 0°C
Maximum Operating Temperature +100°C
300 In stock - FREE next working day delivery available
Price Each (In a Bag of 100)
£ 2.914
(exc. VAT)
£ 3.497
(inc. VAT)
Units
Per unit
Per Bag*
100 - 100
£2.914
£291.40
200 +
£2.841
£284.10
*price indicative
Related Products
Application-optimised and prewired combined lightning current and surge ...
Description:
Application-optimised and prewired combined lightning current and surge arrester for TN-S systems with a nominal voltage of 230 / 400 V (4+0 configuration), with floating remote signalling contact. Application-optimised and prewired spark-gap-based type 1 + type 2 combined lightning current and surge arrester Compact design due to space-saving spark gap ...
Boxes pre-mounted with arrangements of DSP DEHNventil Spark-gap-based ...
Description:
Boxes pre-mounted with arrangements of DSP DEHNventil Spark-gap-based combined lightning current and surge arresters in accordance to BSEN B62305-4 for lightening protection zones. Quick and easy to install RADAX-Flow current limitation maximising system availability20A gl/gG Fuses do not trip with short circuit currents of up to 50k ArmsUp to 50kA ...
DEHNguard Modular Type 2 surge arrestors, supplied as ...
Description:
DEHNguard Modular Type 2 surge arrestors, supplied as a prewired base with plug in modules. Energy coordinated with other Dehn Redline products in accordance with BS7671 amendment 1High discharge capacity using heavy duty metal oxide varistors and spark gaps Status indication using Thermo Dynamic Control for monitoring of the SPDTool ...
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage ...