FireHawk Safety Products Optical Smoke Detector

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Firehawk FHB10W Series Wireless Battery Operated Smoke Alarm

Firehawk FHB10W series battery operated Optical smoke alarms have a 10-year life complete with TSE Thermal Stability Enhancement including Wireless Interlink. The high performing wireless interlink alarm is used and recommended by the UK Fire and Rescue Services. The alarm is specially designed for easy installation and have the same quality as FHB10 smoke alarms. In addition, the alarm features a silence button, audible low battery warning plus, an end of alarm life indicator. The FHB10W series is compatible for use with the FH700HIA sensory alarm system.

FEATURES and BENEFITS:
10-year Optical smoke alarm
TSE – Thermal Stability Enhancement
Intelligent Wireless interlink technology – battery operated
High performing
Smoke detection
Silence buttons
Audible low battery warning
Alarm life indicator
Compatible with Firehawk FH700HIA sensory Alarm
Recommended by the UK Fire and Rescue Services
10-year warranty

Note

RECOMMENDED AND USED BY THE UK FIRE AND RESCUE SERVICES

Standards

EN 14604:2005

Stand Alone Fire Alarms

Battery Operated

A comprehensive range of battery operated smoke alarms all carrying the BS Kitemark and compliance with BS5446:Pt1:1990. They are suitable for BS5839:Pt6:1995 Fire Systems grade F.

Mains Powered Interconnectable

All new properties are required by the Building Regulations to have installed mains powered smoke alarms. Refurbished properties and small commercial premises may also be required to install mains operated alarms.
BS5839:Pt.6:1995 acknowledges that all three types of detection i.e. ionisation, optical and heat detection, need to be considered depending on the installation circumstances. It is also recommended that some form of back-up is used in the event of mains failure.
Optical alarms are recommended for use in circulation spaces such as landings and hallways. Ionisation alarms are more appropriate for use in living rooms and fixed temperature heat alarms are designed for use in kitchens and garages. All alarms must be interconnected using 3 core and earth cable.

At least one alarm on each floor of the house
Max. 7.5m between alarms and no more than 3m from bedroom doors
Alarms can be wired off lighting circuits if the alarm has its own backup supply
Locate as close as possible to centre of ceiling, away from light fitting
Alarms must be kept clean at all times and particularly whilst building work or decoration is in progress

Mains Operated

Suitable for new buildings to allow conformity to building regulations. Each unit features an 85dB at 3m internal alarm and interconection facility which allow the sensing unit to trigger up to 11 other detectors, for added safety and particularly when one unit might not be heard in a large building or from behind closed doors.
The unit causing the alarm also has an indicator to show the source. Each unit has a green continuous LED to indicate mains present.
These products can also be fitted using the surface mounting kits. A relay output option is also available to allow for triggering of remote indicators or other communication/alarm systems. All units are supplied complete with instructions.
290-3816 = 12V Operating Voltage with Relay Output.

Specifications
Attribute Value
Type Optical Smoke Detector
Power Indicator Yes
31 In stock - FREE next working day delivery available
Price Each
£ 43.75
(exc. VAT)
£ 52.50
(inc. VAT)
Units
Per unit
1 +
£43.75
Related Products
Smoke click carries the MAX30105 high-sensitivity optical sensor ...
Description:
Smoke click carries the MAX30105 high-sensitivity optical sensor for smoke detection. The click is designed to run on either 3.3V or 5V power supply. It communicates with the target MCU over I2C interface with additional functionality provided by the INT pin on the mikro BUS™ line.
For detecting visible smoke particles Integrated infrared light ...
Description:
For detecting visible smoke particles Integrated infrared light source generates a light pulse every 8 seconds Visible smoke particles alter the signal received by a photo-diode and the sensor triggers an alarm Self-adjusting sensitivity Floating alarm relay Direct connection to each alarm control unit Recording range 40 m2Mounted to ceiling ...
The new Solo770 Battery Baton is a 3000m ...
Description:
The new Solo770 Battery Baton is a 3000m Ah version of the Solo760 (2200m Ah). It allows greater efficiency on site as it gives more tests per battery, for the same charge time as before but provided by the new Solo 727 charger. Solo 460 Cordless Heat Tester Testifire 1000 ...
Cordless Heat Detector Tester. Portable and cordless, this ...
Description:
Cordless Heat Detector Tester. Portable and cordless, this tester enables testing of heat detectors quickly and easily without the need for mains power. Heat is generated only when the detector under test is within the cup. Hot air is blown horizontally in a focussed beam directly toward the sensor for ...