MTL Crouse-Hinds, Current, Voltage Output, Signal Conditioner

  • RS Stock No. 144-8694
  • Mfr. Part No. MTL1249
  • Brand MTL
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

MTL1249 Signal Converter

MTL1249 is a 1 channel signal conditioner that accepts voltage or current inputs and provides a voltage or current output. The signal levels are selected when using switches on the module. The signal conditioner is DIN Rail mountable.

Features and Benefits

1 Channel voltage/current signal converter
Power supplied via power bus embedded in the DIN Rail
DIN Rail mounting

MTL Signal Conditioners

Specifications
Attribute Value
Input Range 0 → 1 V, 0 → 10 V, 0 → 100 mV, 0 → 2 mA, 0 → 5 V, 1 → 5 V, 4 → 20 mA
Output Range 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA
Supply Voltage 18 → 32 V dc
Mounting Type DIN Rail
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Series Crouse-Hinds
Operating Temperature Range -20 → +60 °C
Number of Channels 1
Termination Screw
Available to back order for despatch 13/11/2020
Price Each
£ 154.00
(exc. VAT)
£ 184.80
(inc. VAT)
Units
Per unit
1 +
£154.00
Related Products
Siemens Sirius 3RS70 signal converters perform the coupling ...
Description:
Siemens Sirius 3RS70 signal converters perform the coupling function for analogue signals on both the input side and the output side. They are indispensable when processing analogue values with electronic controls. Under harsh industrial conditions in particular, it is often necessary to transmit analogue signals over long distances. Electrical separation ...
For Pt100 or thermocouples Measurement range and output ...
Description:
For Pt100 or thermocouples Measurement range and output signal configurable3-way isolation Diagnostic LED for analysing faults Power supply via feed terminal and mounting rail bus connector (stock no. 489-2825) possible Screw or spring-loaded connector Overall width 6.2 mm. MINI MCR - transducer for Pt100 and thermocouples.
Murr Elektronik MTW 12.4 series temperature monitoring relays ...
Description:
Murr Elektronik MTW 12.4 series temperature monitoring relays are designed specially for monitoring abnormal temperatures to prevent excessive temperature increase and to protect equipment. The temperature converter works in conjunction with a PT100 temperature sensor and convert the temperature into a standard output signal. Status LED 2 or 3 wire ...
The Turck flow monitoring for the connection of ...
Description:
The Turck flow monitoring for the connection of flow sensors IO-link device with current and transistor outputs. It has operating voltage 20-30 VDC and power consumption upto 4.5W. It is used for monitoring of operating and display range and detection of wire-break and short-circuit on the sensor side. Adjustment of ...