Schneider Electric XPS BCE 24 V ac/dc Safety Relay With 2 Safety Contacts

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

XPS BCE Series for Two Hand Control, Type IIIC

Incorporates relay outputs for two hand control applications
Compact and robust design
The enclosure has a protection class rating of IP40 and the terminals are protected to IP20
To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval of less than 0.5 s (synchronous activation)
Three LEDs to indicate control/fuse supply, feedback loop and safety output contact status
PL e/Category 4 conforming to EN/ISO 13849-1, SILCL 3 conforming to EN/IEC 62061
Cage clamp and pluggable versions are available

Approvals

UL, CSA, BG

Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Auxiliary Contacts 1
Function Two-Hand Control
Safety Contacts 2
Range Preventa
Terminal Type Screw
Length 99mm
Depth 114mm
Width 22.5mm
4 In stock for delivery within 1 working days
Price Each
£ 261.00
(exc. VAT)
£ 313.20
(inc. VAT)
Units
Per unit
1 +
£261.00
Related Products
The 3-Pole ABB Jokab safety contactor relay has ...
Description:
The 3-Pole ABB Jokab safety contactor relay has a coil voltage 24VDC. It has a contact current rating 50A and contact voltage rating 600VAC. It has low holding consumption up to 1.7W that reduces panel energy consumption. It is with the front marked symbol that guarantees the right contactor status. ...
Relay module with driven contacts, Nominal input voltage: ...
Description:
Relay module with driven contacts, Nominal input voltage: 24 VDC, 2 changeover contacts, Limiting continuous current: 8 A, Red status indicator, Module width: 15 mm. Reinforced insulation between coil and contactsA separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for ...
Relay module, Nominal input voltage: 24 VDC, 2 ...
Description:
Relay module, Nominal input voltage: 24 VDC, 2 changeover contacts, Limiting continuous current: 8 A, Green status indicator, Module width: 15 mm. Reinforced insulation between coil and contactsA separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the ...
Ensures motor movement is at a preset limit ...
Description:
Ensures motor movement is at a preset limit before an output signal is given For use with guard locking interlock switches Fault tolerant principle control unit Monitors contactor operation Dimensions: H73 x W45 x D120mm.