Schneider Electric XPS CM 24 V dc Safety Relay With 2 Safety Contacts

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

XU2 S, Type 2, Single Beam System

The XPS-CM safety module, used in conjunction with the single beam XU2S safety light devices, constitutes a type 2 safety light curtain conforming to IEC 61496-1.

Flexibility allows connection of up to 4 light beam devices which can protect a zone up to 1200mm high and 8m wide (EN999)
Automatic self-checking every 5ms
Built in muting function allows the light device to be inhibited by an external sensor
Single beam sensors (for muting function) available separately
Ideal for transfer line applications
Solid state auxiliary output (from module) PNP 20mA/24Vdc
2 N/O safety outputs

Note

This product is supplied with a full installation instruction manual which should be strictly adhered to. Particular attention should be given to section 3.5 (installation positioning and electrical inter-phasing).

Single Beam Safety Device

Specifications
Attribute Value
Supply Voltage 24 V dc
Auxiliary Contacts 4
Function Light Beam/Curtain
Safety Contacts 2
Range Preventa
Terminal Type Screw
13 In stock for FREE next working day delivery
Price Each
£ 226.00
(exc. VAT)
£ 271.20
(inc. VAT)
Units
Per unit
1 +
£226.00
Related Products
Protection relay with probe, LT3 series, that permanently ...
Description:
Protection relay with probe, LT3 series, that permanently controls the temperature of machines that require protection (motors, alternators etc..). Operates via CTP thermistor probes.Automatic or manual reset.Faults displayed on the front panel of the device or remotely, except for version LT3 SE, which does not have this function.Fault detection if ...
Ensures motor movement is at a preset limit ...
Description:
Ensures motor movement is at a preset limit before an output signal is given For use with guard locking interlock switches Fault tolerant principle control unit Monitors contactor operation Dimensions: H73 x W45 x D120mm.
Monitors the two-hand operation of metal working presses ...
Description:
Monitors the two-hand operation of metal working presses and other processing machines with dangerous lock movements Conforms to amended standard EN574 and therefore safety level III-C for wiring in line with the installation instructions supplied with the device (as at: 02-1997)Safety category in line with. EN954-1:4In accordance with EC directive ...
XPS-MP offers a simple solution for all safety ...
Description:
XPS-MP offers a simple solution for all safety applications and reduces the number of ordering references needed by combining 15 pre-determined functions that are all certified Designed to monitor 2 safety functions independently, choose from; emergency stop, protective door locking, 2 hand control buttons, safety mats or type 4 light ...